Patients with atherosclerotic cerebrovascular disease were studied to determine the radiation exposure associated with conventional and digital subtraction angiography of the cerebral vessels. The median exposure-area product was 3198 R cm2 (range, 616-5665 R cm2) in the conventional angiography group and 1831 R cm2 (range, 366-4198 R cm2) in the IV digital subtraction angiography (DSA) group. ...
BACKGROUND AND PURPOSE We sought to assess whether contrast-enhanced MR angiography is able to predict the degree of angiographic stenosis of the internal carotid artery within a clinically acceptable margin of error, thereby decreasing the need for angiography. In addition, we sought to assess whether adding ultrasound peak systolic velocity (PSV) as an additional regressor improves the accura...
The performance of an automatic technique for the reduction of patient motion artifacts in digital subtraction angiography was evaluated. Four observers assessed the quality of 104 cerebral digital subtraction angiographic images that were processed by means of both the automatic technique and manual pixel shifting. The automatic technique resulted in better image quality and was considerably l...
Subarachnoid hemorrhage secondary to ruptured aneurysm is a critical clinical situation demanding a very skilled surgical and medical management. Until now cerebral digital subtraction angiography (DSA) has been used as the criterion standard for aneurysmal detection and planning of their microsurgical treatment. However, as the method for diagnosis of subarachnoid hemorrhage moved from lumbar ...
PURPOSE Our purpose was to evaluate intraaneurysmal blood velocity by using time-density curve analysis and digital subtraction angiography. METHODS In 31 aneurysms, aneurysmal blood velocity was examined with digital subtraction angiography to determine mean transit time (MTF), peak density time (time to peak opacification) (PDT), and time to half-peak opacification (T1/2). Thirty frames per...
An inexpensive, simplified flow model for use with digital subtraction angiographic (DSA) equipment is described. System tests show that the model gives reproducible data with a standard deviation of +/- 2.6%. Flow analysis also reveals an appropriate response to flow rates of 20-240 ml per min. The flow model can be used to investigate many of the variables and sources of error in DSA flow mea...
INTRODUCTION Ultrasound can visualize and update the vessel status in real time during cerebral vascular surgery. We studied the depiction of parent vessels and aneurysms with a high-resolution 3D intraoperative ultrasound imaging system during aneurysm clipping using rotational digital subtraction angiography as a reference. METHODS We analyzed 3D intraoperative ultrasound in 39 patients wit...