نتایج جستجو برای: crossed screws

تعداد نتایج: 19758  

Journal: :Orthopedics 2013
Shan-Wei Yang Shyh Ming Kuo Shwu Jen Chang Tian-Shiang Su Hsiang-Ho Chen Jenn-Huei Renn Ting-Sheng Lin

The goal of this study was to compare the biomechanical stability of cannulated locking screws and noncannulated cortical locking screws in a periarticular locking plate. Twelve fresh-frozen porcine tibias with a 1-cm gap created distal to the tibial plateau were used to simulate an unstable proximal tibial fracture. All specimens were fixed with a periarticular proximal lateral tibial locking ...

Journal: :Singapore medical journal 2017
Yunus Güzel Mehmet Elmadag Gokcer Uzer Fatih Yıldız Kerem Bilsel İbrahim Tuncay

INTRODUCTION The risk of surgery-related infection is a persistent problem in orthopaedics and infections involving implants are particularly difficult to treat. This study explored the responses of bone and soft tissue to antimicrobial-coated screws. We investigated whether such screws, which have never been used to fix bony tissues, would result in a cytotoxic effect. We hypothesised that the...

2014
S. Y. Heo N. S. Kim

The study compared the bone response to xenogenic screws and metallic screws of a similar design in a canine femur. The xenogenic bone screws and metallic bone screws were inserted into the femur diaphyses of dogs. Radiological and histological responses to the xenogenic bone screws were determined in canine bone and micro-computed tomography evaluation of bone mass and bone density parameter w...

Journal: :Injury 2005
David J Hak James Nguyen Shane Curtiss Scott Hazelwood

This study evaluated different fixation methods in posterior femoral condyle coronal fractures. A standardised osteotomy was created in synthetic composite femurs and fixed with one of four methods (one 3.5 mm diameter screw, two 3.5 mm screws, one 6.5 mm screw, two 6.5 mm screws). The stiffness and mean loads to specified displacements were measured. The stiffness of two 6.5 mm screws was sign...

Journal: :Journal of orthopaedic surgery 2015
Harun Mutlu Serhat Mutlu

PURPOSE To compare the compressive strength of cannulated versus non-cannulated cancellous screws for undisplaced femoral neck fractures in synthetic bones. METHODS 18 synthetic proximal femurs simulating an AO B1 valgus impacted femoral neck fracture in osteoporotic bone were used. The fracture angles were between 55º and 63º (Pauwels grade 2). Fixation was made using 6.5-mm non-cannulated s...

Journal: :Acta of bioengineering and biomechanics 2017
Jiri Marvan Zdenek Horak Miloslav Vilimek Lukas Horny David Kachlik Vaclav Baca

Ankle fractures are complex injuries with variable prognoses that depend upon many factors. The aim of the treatment is to restore the ankle joint biomechanical stability with maximum range of motion. Most ankle fractures are fibular fractures, which have a typical oblique fracture line in the distal fibula located in the area of the tibiofibular syndesmosis. The aim of this study was to simula...

2013
Chang Hyun Oh Seung Hwan Yoon Yongjung J. Kim Dongkeun Hyun Hyeong-Chun Park

OBJECTIVE A variety of different pedicle screws entry point techniques are used for the lumbar pedicle screws placement. This study reported Kim's entry point of lumbar pedicle screws with free hand technique and the accuracy of this technique. METHODS We retrospectively reviewed the 584 cases with free hand placed lumbar pedicle screw placement. The diagnosis included 491 cases with degenera...

Journal: :Brazilian oral research 2014
Eduardo Aloisio Fleck Neumann Cristina Cunha Villar Fabiana Mantovani Gomes França

Fractured abutment screws may be replaced; however, sometimes, the screw cannot be removed and the entire implant must be surgically removed and replaced. The aim of this study was to compare the fracture resistance of abutment retention screws made of titanium, polyetheretherketone (PEEK) and 30% carbon fiber-reinforced PEEK, using an external hexagonal implant/UCLA-type abutment interface ass...

Journal: :The Journal of bone and joint surgery. British volume 1997
G Magyar S Toksvig-Larsen A Moroni

We measured the insertion and extraction torque forces in a randomised study of 76 external fixation screws in 19 patients treated by hemicallotasis for osteoarthritis of the medial side of the knee. The patients were randomised to have either standard tapered screws (Orthofix 6/5 mm) or the same screws with hydroxyapatite (HA) coating. One patient had two standard and two HA-coated screws. All...

Journal: :Clinical biomechanics 2014
Jan Christoph Katthagen Michael Schwarze Josefin Meyer-Kobbe Christine Voigt Christof Hurschler Helmut Lill

BACKGROUND The objective of this study was to investigate the biomechanical effects of medial fracture gap augmentation in locked plating of an unstable 2-part proximal humeral fracture with calcar screws and insertion of a corticocancellous bone block. Furthermore the mechanical behavior of dynamic locking screws in the non-parallel arrangement of a proximal humeral plate was of interest. ME...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید