نتایج جستجو برای: contact lens wear

تعداد نتایج: 232021  

Journal: :British Journal of Ophthalmology 1999

Journal: :Ophthalmic plastic and reconstructive surgery 2011
D Julian de Silva J Richard O Collin

PURPOSE To assess the outcome of surgery in patients with a history of contact lens wear. DESIGN Retrospective, comparative interventional case series. METHODS A total of 419 patients underwent ptosis surgery during a 1-year period (2005-2006) at Moorfields Eye Hospital. Those included in this study had a diagnosis of aponeurotic ptosis and history of contact lens wear. MAIN OUTCOME MEASU...

Journal: :Optometry and vision science : official publication of the American Academy of Optometry 2011
Heidi Wagner Robin L Chalmers G Lynn Mitchell Meredith E Jansen Beth T Kinoshita Dawn Y Lam Timothy T McMahon Kathryn Richdale Luigina Sorbara

PURPOSE The purpose of this study was to describe age and other risk factors for ocular events that interrupt soft contact lens (SCL) wear in youth. METHODS A retrospective chart review of SCL wearers aged 8 to 33 years at the first observed visit was conducted at six academic eye care centers in North America. Data were extracted from all visits during the observation period (>3 years). Clin...

Journal: :Ophthalmology 2015
Helen A Swarbrick Ahmed Alharbi Kathleen Watt Edward Lum Pauline Kang

PURPOSE To investigate the effect of overnight orthokeratology (OK) contact lens wear on axial length growth in East Asian children with progressive myopia. DESIGN A prospective, randomized, contralateral-eye crossover study conducted over a 1-year period. PARTICIPANTS We enrolled 26 myopic children (age range, 10.8-17.0 years) of East Asian ethnicity. METHODS Subjects were fitted with ov...

Journal: :Contact lens & anterior eye : the journal of the British Contact Lens Association 2015
James Wolffsohn Lee Hall Stephanie Mroczkowska Olivia A Hunt Paramdeep Bilkhu Tom Drew Amy Sheppard

PURPOSE To quantify the end-of-day silicone-hydrogel daily disposable contact lens fit and its influence of on ocular comfort, physiology and lens wettability. METHODS Thirty-nine subjects (22.1±3.5 years) were randomised to wear each of 3 silicone-hydrogel daily-disposable contact lenses (narafilcon A, delefilcon A and filcon II 3), bilaterally, for one week. Lens fit was assessed objectivel...

Journal: :Contact lens & anterior eye : the journal of the British Contact Lens Association 2014
Aoife Lloyd McKernan Veronica O'Dwyer Luisa Simo Mannion

INTRODUCTION Accurate corneal measurements are crucial in corneal refractive surgery (CRS) to ensure successful outcomes. Soft contact lens (SCL) wear may result in changes to corneal curvature and structure. United States Food and Drug Administration (FDA) pre-operative guidelines recommend that prior to CRS, SCL wearers cease SCL wear for "at least two weeks before examination and treatment" ...

2016
Jason J. Nichols Christopher W. Lievens Marc R. Bloomenstein Haixia Liu Peter Simmons Joseph Vehige

PURPOSE This study compared a new contact lens rewetting drop containing both carboxymethylcellulose and hyaluronic acid (CMC-HA) with a standard drop containing carboxymethylcellulose only (CMC). Symptoms of discomfort typical in lens wear and lid wiper epitheliopathy (LWE) were assessed over a 3-month period in a diverse sample of contact lens wearers. METHODS Adapted daily-wear contact len...

Journal: :Clinical & experimental optometry 2017
Nathan Efron Philip B Morgan

The evolution of contact lens technology and clinical practice over the past three decades has been remarkable, with dramatic improvements in material biocompatibility, better lens designs and care systems, and more flexible and convenient modalities of wear. However, our approach to the aftercare examination has remained conservative, with the general modus operandi having not fully evolved fr...

Journal: :Investigative ophthalmology & visual science 1999
W M Bourne D O Hodge J W McLaren

PURPOSE To study the effects of long-term contact lens wear on morphologic and physiologic properties of corneal endothelial cells. METHODS The endothelial permeability to fluorescein and the rate of corneal deswelling from hypoxia-induced edema were measured in 20 long-term (mean, 17+/-9 years; range, 5-33 years) contact lens wearers and 20 age-matched control subjects. From these data, the ...

Journal: :international journal of preventive medicine 0
hasan razmjoo elham abdi sayna atashkadi mohamad reza akhlaghi ali reza peyman mojtaba akbari

background: silicon hydrogel bandage contact lenses are used to enhance epithelial healing, control surface-generated pain, and prevent epithelial erosions after refractive surgery. considering the importance of faster reepithelialization in preventing complications of photorefractive keratectomy (prk) and the fact that the features and specifications of these commercially-available lenses are ...

نمودار تعداد نتایج جستجو در هر سال