نتایج جستجو برای: compression plate

تعداد نتایج: 162389  

2012
Michael P. Kowaleski

The advent of internal fixation with bone plates and screws represents a tremendous advancement in the methods of fracture fixation. During this era, the emphasis was on anatomic reconstruction and rigid internal fixation. Although these principles are applicable to a great number of fractures, not all can be treated in this manner. In fact, the disruption of the soft tissue envelope required t...

Journal: :The Journal of bone and joint surgery. American volume 2008
Rad Zdero Richard Walker James P Waddell Emil H Schemitsch

BACKGROUND A variety of methods are available for the fixation of femoral shaft fractures after total hip arthroplasty. However, few studies in the literature have quantified the performance of such repair constructs. The aim of this study was to evaluate biomechanically four different constructs for the fixation of periprosthetic femoral shaft fractures following total hip arthroplasty. METH...

Journal: :Journal of orthopaedic surgery 2016
P H Wu L Shen Y H Chee

PURPOSE To compare the outcome following headless compression screw fixation versus radial head arthroplasty versus plate fixation for 3-part Mason types III or IV radial head fracture. METHODS Records of 25 men and 16 women aged 21 to 80 (mean, 43.3) years who underwent fixation using 2 to 3 2-mm cannulated headless compression screws (n=16), radial head arthroplasty (n=13), or fixation with...

Journal: :The Journal of bone and joint surgery. British volume 2008
J J H Leong D R Leff A Das R Aggarwal P Reilly H D E Atkinson R J Emery A W Darzi

The aim of this study was to validate the use of three models of fracture fixation in the assessment of technical skills. We recruited 21 subjects (six experts, seven intermediates, and eight novices) to perform three procedures: application of a dynamic compression plate on a cadaver porcine model, insertion of an unreamed tibial intramedullary nail, and application of a forearm external fixat...

2010
Markus Windolf Kajetan Klos Dirk Wähnert Bas van der Pol Roman Radtke Karsten Schwieger Roland P Jakob

BACKGROUND Angle-stable locking plates have improved the surgical management of fractures. However, locking implants are costly and removal can be difficult. The aim of this in vitro study was to evaluate the biomechanical performance of a newly proposed crossed-screw concept ("Fence") utilizing conventional (non-locked) implants in comparison to conventional LC-DCP (limited contact dynamic com...

Journal: :The Journal of bone and joint surgery. British volume 1986
P W Skinner D Powles

We report a prospective study of 198 cases of subcapital fracture of the femur treated by closed reduction and fixation with a sliding compression screw-plate. This was done without regard to the patient's age or the Garden stage of the fracture. Early weight-bearing was encouraged. Of the displaced fractures 23% failed in the first year because of non-union or infection. Of the fractures which...

2013
S.A. Siddiqui M.I. Siddiqui M.N. Telfah S. Hashmi

An oblique fracture of the distal third of the right metatarsus in a three-year-old dromedary heifer weighing about 300 kilograms was immobilized with a 4.5 mm broad-webbed 12-hole dynamic compression bone plate and two interfragmental compression screws. The animal showed slight lameness after 16 weeks of surgery that disappeared after removal of the plate. The result was quite encouraging and...

Journal: :Journal of orthopaedic surgery 2005
K K Wong K W Chan T K Kwok K H Mak

PURPOSE To evaluate the functional and radiological results of treating unstable fractures of the dorsal distal radius with a volar locking plate. METHODS Dorsally displaced distal radial fractures in 30 patients (11 men and 19 women; mean age, 58.6 years) were fixed by volar locking compression plate and followed up for a minimum of one year. RESULTS At final functional assessment, 24 pati...

2010
Ji Su Jang Hyung Ki Kwon Jae Jun Lee Sung Mi Hwang So Young Lim

Histologically, Schmorl's nodes are defined as the loss of nuclear material through the cartilage plate, growth plate, and end plate into the vertebral body. Most Schmorl's nodes are asymptomatic, although there are some reports of symptomatic Schmorl's nodes, which should be treated similarly to vertebral compression fractures, with conservative treatment as the first choice. We report the cas...

Journal: :Acta orthopaedica Belgica 2012
Ghislain F A E Geurts Roger P Van Riet Frederik Verstreken

A case is presented of a 78-year-old woman who sustained a re-fracture of the distal radius after initial fixation with a volar locking plate. The fracture was located in the mid-portion of the volar plate with palmar apex bending of the plate and signs of median nerve compression. A successful closed reduction was performed without hardware failure. The fracture united uneventfully.

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید