نتایج جستجو برای: clinical dosimetry

تعداد نتایج: 1168967  

Journal: :Physics in medicine and biology 2003
F Sánchez-Doblado P Andreo R Capote A Leal M Perucha R Arráns L Núñez E Mainegra J I Lagares E Carrasco

Absolute dosimetry with ionization chambers of the narrow photon fields used in stereotactic techniques and IMRT beamlets is constrained by lack of electron equilibrium in the radiation field. It is questionable that stopping-power ratio in dosimetry protocols, obtained for broad photon beams and quasi-electron equilibrium conditions, can be used in the dosimetry of narrow fields while keeping ...

2013
M. Benabdesselam F. Mady S. Girard

This study analyses the thermally stimulated luminescence (TSL) or thermoluminescence glow curve between 300 and 773 K of germanium-doped silica optical fibre and finds a main glow peak at around 500 K with a characteristic spectral emission centred at 400 nm. Both features are particularly suitable for dosimetry. Thus, an investigation by the TSL technique of some first clinically relevant fea...

Ghorban Safaeian Mohammad Hosein Bahreyni Toossi Mohammad Taghi Bahreyni Toossi, Shahram Baiani

Introduction: The purpose of this work was to study the ability of MRI normoxic polymer gel dosimetry for evaluating the dose distribution in HDR brachytherapy of esophagial cancer at Imam Reza brachytherapy center (Mashhad, Iran). Materials and Methods: Initially, 2liters of normoxic gel (MAGIC) was fabricated and then poured into 12 calibration test tubes and placed in a perspex walled phanto...

Journal: :Physics in medicine and biology 2015
Gustav Brolin Johan Gustafsson Michael Ljungberg Katarina Sjögreen Gleisner

Patient-specific image-based dosimetry is considered to be a useful tool to limit toxicity associated with peptide receptor radionuclide therapy (PRRT). To facilitate the establishment and reliability of absorbed-dose response relationships, it is essential to assess the accuracy of dosimetry in clinically realistic scenarios. To this end, we developed pharmacokinetic digital phantoms correspon...

Journal: :Medical physics 2001
M Oldham J H Siewerdsen A Shetty D A Jaffray

The increased intricacy of Intensity-Modulated-Radiation-Therapy (IMRT) delivery has created the need for a high-resolution 3D-dosimetry (three-dimensional) system capable of measuring and verifying the complex delivery. Present clinical methods are inadequate being restricted to single points (e.g., ion-chambers) or to 2D planes (e.g., film), and are labor intensive. In this paper we show that...

2017
Silvano Gnesin Periklis Mitsakis Francesco Cicone Emmanuel Deshayes Vincent Dunet Augusto F Gallino Marek Kosinski Sébastien Baechler Franz Buchegger David Viertl John O Prior

BACKGROUND Integrin-targeting radiopharmaceuticals have potential broad applications, spanning from cancer theranostics to cardiovascular diseases. We have previously reported preclinical dosimetry results of 68Ga-NODAGA-RGDyK in mice. This study presents the first human dosimetry of 68Ga-NODAGA-RGDyK in the five consecutive patients included in a clinical imaging protocol of carotid atheroscle...

2014
Mauro Valente Francisco Malano Pedro Pérez

Nuclear medicine clinical practices for neoplasic disease diagnose and treatment are based on the incorporation of α , β and γ radiotracers and radiopharmaceuticals, which might be associated with potential damage. Thus, being necessary accurate dosimetry strategies. In vivo absorbed dose appears as an ideal solution. However, its implementation in clinics does not attain enough reliability. In...

2016
P. Woulfe F. J. Sullivan S. O’Keeffe

Review is made of dosimetric studies of current optical fibre technology in radiotherapy for therapeutic applications, focusing particularly on in vivo dosimetry for prostate radiotherapy. We present the various sensor designs along with the main advantages and disadvantages associated with this technology. Optical fibres are ideally placed for applications in radiotherapy dosimetry; due to the...

2010
Reichmann

Dosimetry is the process of calculating the effective radioactive dose that is applied to tumors and organs respectively as a patient undergoes a peptide receptor radionuclide therapy. This work presents the novel application software ‘DoSE8’ that was developed from our group and that incorporates all necessary image processing steps (registration and segmentation) and data handling for (partly...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید