نتایج جستجو برای: c18 column

تعداد نتایج: 77572  

Journal: :Journal of chromatography. B, Analytical technologies in the biomedical and life sciences 2008
Michele C Kelly Blánaid White Malcolm R Smyth

This study involves the incorporation of a commercially available Phenomenex Onyx C18 monolith column into the separation and detection of oxidative DNA damage. It includes thorough investigation of monolith performance and a comparison of the performance of monolith columns with a commercially available packed Restek reverse phase Ultra C18 column for the separation of DNA bases and nucleoside...

2009
M. M. Rohman T. Suzuki

A glutathione S-transferase (GST, EC 2.5.1.18) inhibitor was isolated from the onion bulb by fractionation and purification using Sep-pak Vac C18 column, TLC and HPLC. Five partially purified onion bulb GSTs (GSTa and GSTb as minor GSTs, and GSTc, GSTd and GSTe as dominant GSTs) separated by DEAE column were used to detect the inhibitory substance in onion bulb extract. Among the three fraction...

2013

This application note describes a fast UHPLC method for the determination of 20 ginsenosides. The developed method allows for the determination of 20 ginsenosides in less than 35 minutes. A binary high pressure gradient is used at a flow rate of 0.6 ml/min. By applying a Bluespher 100-2 C18 column in the dimension 150 x 2 mm ID, the total run time could be reduced to less than 41 minutes when a...

2009
Ankur Doshi Varun Trivedi Priyanka Sehgal Amar S. Basu

Generating chemical libraries in droplet form is vital to the adoption of microdroplet systems in high-throughput screening (HTS). This paper presents microfractionation in droplets (μFD), a method for generating heterogeneous droplet libraries using standard separation processes. In μFD, compounds eluting from a separation column are permanently encapsulated into droplets by a droplet generato...

2011
M V Kumudhavalli

A simple, precise, rapid and accurate RP-HPLC method has been developed for the simultaneous estimation of Amlodipine besylate and Hydrochlorthiazide in tablet formulations. The chromatographic separation was achieved on a Shimadzu Symmetry C18 column (250 mm x 4.6mm, 5.0 μ particle size) using Methanol: Acetonitrile: 50mM Na2HPO4 pH7.0 (60:20:20v/v/v) with 1% triethylamine. Flow rate was 1ml/m...

Journal: :International journal of biomedical science : IJBS 2015
Moataz S Hendy

New UPLC method was developed for determination of sitagliptin and metformin using Symmetry C18 column (100 mm × 2.1 mm, 2.2 μm) and isocratic elution (methanol 20%), pH (3.5) as a mobile phase. The ultraviolet detector was operated at 220 nm and the column temperature was 50°C. Linearity parameters were acceptable over the concentration ranges of 2-12 μgml(-1) and 5-35 μgml(-1) for sitagliptin...

2015
Xinwu Huang Mingli Sun Guochun Li

To establish the method for qualitative and quantitative determination of gallic acid in Herba Gei. Gallic acid content is determined by HPLC with Diamonsil C18 column as the stationary phase, under the conditions of methanol-0.1% phosphoric acid in water (10:90) mobile phase, 271 nm detection wavelength, and 40°C column temperature. Peak area of gallic acid shows a good linearity with the inje...

Journal: :Analytical biochemistry 2017
Peter Kesa Mangesh Bhide Veronika Lysakova Andrey Musatov

A rapid separation of the ten nuclearly-encoded subunits of mitochondrial cytochrome c oxidase, and ten out of the eleven subunits of cytochrome bc1, was achieved using a short, 50 mm C18-reversed-phase column. The short column decreased the elution time 4-7 fold while maintaining the same resolution quality. Elution was similar to a previously published protocol, i.e., a water/acetonitrile elu...

2012
Prameela Rani Seelam Harika

A new simple isocratic RP-HPLC method was developed for the determination of milnacipran in bulk drug and in its capsules formulations. The mobile phase selected was methanol: acetonitrile:0.1% O-phosphoric acid in the ratio of 55:35:10%(v/v) and Zodiac C18 column with dimensions (250X4.6mm, 5μ)was used as stationary phase column temperature is ambient throughout the method. The flow rate and w...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید