Unregulated utilization of renewable generation including residential photovoltaic (PV) systems can have a significant impact on load characteristics in distribution networks. For improving PV generation capabilities, power quality aspects have to be coordinated with present load characteristics. This paper discusses the harmonic content of PV generation and the influence to power quality indic...
In this paper, the first system of the IEEE second benchmark model (SBM) for subsynchronous resonance (SSR) studies is analyzed using the bifurcation theory. A nonlinear model for the SBM which consists of a synchronous generator connected to an infinite busbar through two parallel transmission lines, one of which is equipped with a series capacitor, has been developed in MATLAB. Generator damp...
In this paper, a new numerical method of calculating rectangular busbar impedance is proposed. This method is based on integral equation method and partial inductance theory. In particular, impedances of shielded and unshielded three-phase systems with rectangular phase and neutral busbars, conductive enclosure, and use of the method are described. Results for resistances and reactances for the...
In this paper, a novel approach to analyse, extract and validate the key characteristics of the fault transient phenomena on a thyristor controlled series capacitor (TCSC) compensated transmission line is introduced. This method relies on utilising discrete wavelet transform (DWT) to decompose the traditional busbar voltages and line currents obtained from a single terminal into a series of tim...
Dispersed sources can cause significant voltage changes in the MV and LV distribution grids, which common voltage regulation of the grid by on-load tap changing of HV/MV power transformers can neither find nor respond to in an appropriate and effective way. In the proposed solution, stabilization of the voltage is preferably achieved by power factor or reactive power regulation (PF / Q) of conn...
This paper reports on the development of integrated protection for power system. The background of the development is firstly introduced, in which a centralized protection system (or relay) provides the protection of multiple power plant or a substation. A novel integrated protection scheme for distribution system based on overcurrent protection technique is described. In the proposed scheme, s...
The paper presents a new algorithm, its implementation, and results of extensive testing, for a microprocessor-based lowimpedance busbar relay. For increased security, the presented technique combines percent differential and current directional protection principles. The directional (phase comparison) principle does not require a voltage signal as it responds to relative directions of the curr...
Large perceptual class motor load is the main production equipment of metallurgical enterprise, although has taken independent secondary substation power supply mode, but due to the influence of the impact load, Often appears on the bus voltage drop and low power factor and harmonic big problems, , this article is based on SVC compensation control mechanism, the sectional control mode, the prin...