نتایج جستجو برای: brachytherapy tg 43 formalism

تعداد نتایج: 156742  

Journal: :Medical physics 2012
Luc Beaulieu Asa Carlsson Tedgren Jean-Francois Carrier Stephen D Davis Firas Mourtada Mark J Rivard Rowan M Thomson Frank Verhaegen Todd A Wareing Jeffrey F Williamson

The charge of Task Group 186 (TG-186) is to provide guidance for early adopters of model-based dose calculation algorithms (MBDCAs) for brachytherapy (BT) dose calculations to ensure practice uniformity. Contrary to external beam radiotherapy, heterogeneity correction algorithms have only recently been made available to the BT community. Yet, BT dose calculation accuracy is highly dependent on ...

Background: HDR brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. In this method, depending on how advanced one tumor is, 2 to 6 Gy dose as intracavitary brachytherapy is prescribed. Due to high dose rate and tumor location, accuracy evaluation of treatment planning system (TPS) is particularly important. Common methods used in TPS dosimetry are based on computat...

2015
K. Hadad M. Zohrevand R. Faghihi A. Sedighi Pashaki

BACKGROUND HDR brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. In this method, depending on how advanced one tumor is, 2 to 6 Gy dose as intracavitary brachytherapy is prescribed. Due to high dose rate and tumor location, accuracy evaluation of treatment planning system (TPS) is particularly important. Common methods used in TPS dosimetry are based on computati...

2017
Ron S. Sloboda Hali Morrison Brie Cawston-Grant Geetha V. Menon

Model-based dose calculation algorithms (MBDCAs) have recently emerged as potential successors to the highly practical, but sometimes inaccurate TG-43 formalism for brachytherapy treatment planning. So named for their capacity to more accurately calculate dose deposition in a patient using information from medical images, these approaches to solve the linear Boltzmann radiation transport equati...

Journal: :journal of biomedical physics and engineering 0
k hadad shiraz university m zohrevand shiraz university r faghihi shiraz university a sedighi pashaki mahdieh m.r.i center, hamedan

background: hdr brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. in this method, depending on how advanced one tumor is, 2 to 6 gy dose as intracavitary brachytherapy is prescribed. due to high dose rate and tumor location, accuracy evaluation of treatment planning system (tps) is particularly important. common methods used in tps dosimetry are based on computat...

2018
Irina Fotina Kyveli Zourari Vasileios Lahanas Evaggelos Pantelis Panagiotis Papagiannis

Purpose To perform a comparative study of heterogeneities and finite patient dimension effects in 60Co and 192Ir high-dose-rate (HDR) brachytherapy. Material and methods Clinically equivalent plans were prepared for 19 cases (8 breast, 5 esophagus, 6 gynecologic) using the Ir2.A85-2 and the Co0.A86 HDR sources, with a TG-43 based treatment planning system (TPS). Phase space files were obtaine...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2002
Ali S Meigooni Maung M Yoe-Sein Awni Y Al-Otoom Keith T Sowards

The TG-43 recommended dosimetric characteristics of a new 125I brachytherapy source have been experimentally and theoretically determined. The measurements were performed in Solid Water using LiF TLDs. The calculations were performed using Monte Carlo simulations in Solid Water and water. The measured data were compared with calculated values as well as the reported data in literature for other...

2008
A. A. Mowlavi F. Cupardo M. Severgnini

Theoretical and experimental studies have been applied for dosimetric parameters determination of the brachytherapy sources (1-3). Usually, Monte Carlo method has been used to define such quantities as the anisotropy dose function, the radial dose function, and the dose calculation close to the source in brachytherapy (4-6). Ir source is used widely in brachytherapy to treat localized tumors ne...

2008
Jessica Hiatt Gene Cardarelli Jaroslaw Hepel David Wazer Edward Sternick

In this work, we report a comprehensive quality assurance (QA) process for the commissioning of an Electronic Brachytherapy (EB) system at one of the first U.S. sites to apply the device clinically. Thus far, EB systems have been released only for intracavitary breast treatments. As such, EB as an Accelerated Partial Breast Irradiation (APBI) treatment modality is relatively unstudied and is un...

Journal: :Physics in medicine and biology 2015
Fernando Hueso-González Javier Vijande Facundo Ballester Jose Perez-Calatayud Frank-André Siebert

In low energy brachytherapy, the presence of tissue heterogeneities contributes significantly to the discrepancies observed between treatment plan and delivered dose. In this work, we present a simplified analytical dose calculation algorithm for heterogeneous tissue. We compare it with Monte Carlo computations and assess its suitability for integration in clinical treatment planning systems. T...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید