Journal: :BMC Infectious Diseases 2008
Neema Mtunthama Stephen B Gordon Temwa Kusimbwe Eduard E Zijlstra Malcolm E Molyneux Neil French

BACKGROUND Blood culture surveillance will be used for assessing the public health effectiveness of pneumococcal conjugate vaccines in Africa. Between 2003 and 2006 we assessed blood culture outcome and performance in adult patients in the central public hospital in Blantyre, Malawi, before and after the introduction of a dedicated nurse led blood culture team. METHODS A prospective observati...

2014
Zhiping Wang

It is vital to evaluate the volume of the absorbing capacity and the amount of bleeding during endoscopic surgery. However, the monitoring equipment has been blank because of the monitoring methods applied currently have their inborn deficiency. The aim of this project is to design an intelligent system to monitor irrigating fluid absorption and blood loss in the endoscopic surgery rapidly and ...

2014
Zhongcheng Xin

It is vital to evaluate the volume of the absorbing capacity and the amount of bleeding during endoscopic surgery. However, the monitoring equipment has been blank because of the monitoring methods applied currently have their inborn deficiency. The aim of this project is to design an intelligent system to monitor irrigating fluid absorption and blood loss in the endoscopic surgery rapidly and ...

E Baghizadeh, H Khara ,

The purpose of this study was to determine changes in hematological and plasma indices of Common Carp Cyprinus carpio with regard to age, sex and hormonal treatment. Sixty fish were used to assess the age factor. Also, 20 fish including female and male were assigned to determine blood indices with regard to sex and hormonal treatment. The pituitary gland extract was used as hormone for males an...

2006
Soo-Jeong Yu Do-hyoung Kim Dong-Jin Oh Suk-Hee Yu Eung-Tack Kang

Fluid shifts are commonplace in chronic hemodialysis patients during the intra- and interdialytic periods. In this study, we evaluated fluid shifts of body compartments using both bioimpedance spectroscopy and blood volume monitoring from the start to the end of hemodialysis. 24 stable hemodialysis patients were included on the study. Relative change of blood volume was progressively reduced fr...

Journal: :hepatitis monthly 0
seiyed mohammad ali ghayumi department of internal medicine, shiraz university of medical sciences, shiraz, ir iran abolfazl khalafi-nezhad department of internal medicine, shiraz university of medical sciences, shiraz, ir iran; corresponding author: abolfazl khalafi-nezhad, department of internal medicine, shiraz university of medical sciences, shiraz, ir iran. tel: +98-7116474316, fax: +98-7116474316, e-mail: zahra jowkar department of operative dentistry, school of dentistry, shiraz university of medical sciences, shiraz, ir iran

results roc-derived spo2 threshold of ≤ 94% can predict hypoxemia (pao2 < 60 mmhg) with a sensitivity of 100% and a specificity of 95%. furthermore, there are associations between the roc-derived spo2 threshold of ≤ 97% and detection of hypoxemia (pao2 < 70 mmhg) with a sensitivity of 100% and a specificity of 46%. the accuracy of pulse oximetry was not affected by the severity of liver disease...

Journal: :Nephron. Clinical practice 2011
John Booth Jennifer Pinney Andrew Davenport

INTRODUCTION Intradialytic hypotension remains the most common complication for outpatient hemodialysis, and relative blood volume monitoring was designed to reduce hypotension. Reports of the usefulness of this technology, however, have been variable. METHODS We audited the usefulness of relative blood volume monitoring recorded throughout the mid-week dialysis in 72 stable adult outpatients...

Journal: :Blood purification 2013
Stephan Thijssen Franz Kappel Peter Kotanko

Intradialytic hypotension (IDH) is the most common complication during hemodialysis and is associated with significant morbidity. It occurs as a consequence of a reduction in blood volume during ultrafiltration. Today, devices for monitoring relative blood volume (i.e. the intradialytic blood volume as a fraction of the blood volume at the start of the dialysis treatment) are routinely availabl...