نتایج جستجو برای: applicator stick

تعداد نتایج: 10092  

2018
Mohammad Hosein Sadeghi Sedigheh Sina Amir Mehdizadeh Reza Faghihi Vahed Moharramzadeh Ali Soleimani Meigooni

Purpose The dosimetry procedure by simple superposition accounts only for the self-shielding of the source and does not take into account the attenuation of photons by the applicators. The purpose of this investigation is an estimation of the effects of the tandem and ovoid applicator on dose distribution inside the phantom by MCNP5 Monte Carlo simulations. Material and methods In this study,...

2015
Chin-Hui Wu Yi-Jen Liao An-Cheng Shiau Hsin-Yu Lin Yen-Wan Hsueh Liu Shih-Ming Hsu

Applicators containing metal have been widely used in recent years when applying brachytherapy to patients with cervical cancer. However, the high dose rate (HDR) treatment-planning system (TPS) that is currently used in brachytherapy still assumes that the treatment environment constitutes a homogeneous water medium and does not include a dose correction for the metal material of the applicato...

2012
Kavitha Arunachalam Oana I. Craciunescu Edward J. Markewitz Paolo F. Maccarini Jaime L. Schlorff Paul R. Stauffer

A thermobrachytherapy surface applicator (TBSA) was developed for simultaneous heat and brachytherapy treatment of chest wall (CW) recurrence of breast cancer. The ability to comfortably secure the applicator over the upper torso relative to the CW target throughout treatment is assessed on volunteers. Male and postmastectomy female volunteers were enrolled to evaluate applicator secure fit to ...

2016
Primoz Petric Robert Hudej Noora Al-Hammadi Barbara Segedin

BACKGROUND Standard applicators for cervical cancer Brachytherapy (BT) do not always achieve acceptable balance between target volume and normal tissue irradiation. We aimed to develop an innovative method of Target-volume Density Mapping (TDM) for modelling of novel applicator prototypes with optimal coverage characteristics. Patients and methods. Development of Contour-Analysis Tool 2 (CAT-2)...

2004

Recent interest in the treatment of disseminated intravascular coagulation with heparin (1, 2) has caused some clinicians and laboratory workers to express doubt concerning the accuracy of fibrinogen methods based on thrombin-induced fibrin clot formation and subsequent measurement of the fibrin by biuret methods. It was reasoned that inaccurately low results would be produced owing to the pres...

Journal: :iranian journal of radiation research 0
p. shokrani isfahan university of medical sciences, department of medical physics, isfahan, iran m. soltani isfahan university of medical sciences, department of medical physics, isfahan, iran

background: intraoperative radiation therapy (iort) technique is used to treat a surgically exposed tumor or tumor bed in the treatment of locally advanced intraabdominal, retroperitoneal, pelvic, thoracic, breast and soft tissue tumors. one way to perform iort is to use an existing linac and modify the treatment head using an applicator system. in this study the objectives were to design, and ...

2015
Ileana Iftimia Mike Talmadge Ron Ladd Per Halvorsen

The objective for this work was to develop a commissioning methodology for the treatment delivery components of the AccuBoost system, as well as to establish a routine quality assurance program and appropriate guidance for clinical use based on the commissioning results. Various tests were developed: 1) assessment of the accuracy of the displayed separation value; 2) validation of the dwell pos...

2017
Garrett M. Pitcher Kenneth R. Hogstrom Robert L. Carver

Prototype 10 × 10 and 20 × 20-cm2 electron collimators were designed for the Elekta Infinity accelerator (MLCi2 treatment head), with the goal of reducing the trimmer weight of excessively heavy current applicators while maintaining acceptable beam flatness (±3% major axes, ±4% diagonals) and IEC leakage dose. Prototype applicators were designed initially using tungsten trimmers of constant thi...

2011
Alfred A. Shihata Steven A. Brody

Objectives: 1) HIV prevention, using a mechanical cervical barrier in combination with microbicide. 2) Prevention of pregnancy. 3) Shield the cervix to prevent sperm penetration and Gonorrhea, Chlamydia and HIV virus invasion. Methods: We investigated a new FDA approved cervical barrier FemCap (Figure 1). The FemCap is a contraceptive device that is designed with a unique delivery system for mi...

2017
Leif Karlsson Per Thunberg Anders With Louise Bohr Mordhorst Jan Persliden

PURPOSE Using 3D image-guided adaptive brachytherapy for cervical cancer treatment, it often means that patients are transported and moved during the treatment procedure. The purpose of this study was to determine the intra-fractional longitudinal applicator shift in relation to the high risk clinical target volume (HR-CTV) by comparing geometries at imaging and dose delivery for patients with ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید