نتایج جستجو برای: activating agents and monte carlo code

تعداد نتایج: 16886189  

A. Karimian, A. Rahmim, M.N.  Nasrabadi, N. Ahmadi,

Background: In CT systems, the machine utilizes a bowtie filter to shape the X-ray beam and remove lower energy photons. The shape of this bowtie filter is complicated and its geometry is often not available in detail. These renders the CT dose index (CTDI) to have different values in measurement versus Monte Carlo simulation studies and other analytical calculations especially in dosimetry of ...

جعفر اسماعیلی, , سید ظفراله کلانتری, ,

 In this paper the cycle of muon catalyzed fusion processes has been simulated using Monte-Carlo methods. This simulation starts when muon enters the D/T mixture and follows the actual trajectories of the muonic atoms among the proceeding collisions, by using their cross sections. For this purpose a computer code has been written by Fortran language. The time dependence of the processes is take...

D. Shahbazi-Gahrouei, M. Hosseinpour, M.B. Tavakoli,

Background: For an effective treatment planning in brachytherapy, it is necessary to know the accurate source dosimetric information such as air kerma strength, exposure rate constant, dose rate constant and redial dose distribution. The usual method to determine these factors is thermo luminescent dosimeter (TLD) dosimetry. Nowadays, another more accurate method is known to be the Monte Carlo ...

آقامیری, سید محمود رضا, باغانی, حمیدرضا, حیدرلو, نعمت‌الله, مهدوی, سید ربیع,

Intraoperative electron radiotherapy is one of the radiotherapy methods that delivers a high single fraction of radiation dose to the patient in one session during the surgery. Beam shaper applicator is one of the applicators that is recently employed with this radiotherapy method. This applicator has a considerable application in treatment of large tumors. In this study, the dosimetric charact...

Journal: :iranian journal of radiation research 0
a. mostaar medical physics department, tehran university of medical sciences, tehran, iran m. allahverdi department of radiotherapy physics, cancer institute, tehran, iran m. shahriari gamma irradiation center, atomic energy organization of iran, tehran, iran

background: in treating patients with radiation, the degree of accuracy for the delivery of tumor dose is recommended to be within ± 5% by icru in report 24. the experimental studies have shown that the presence of low-density inhomogeneity in areas such as the lung can lead to a greater than 30% change in the water dose data. therefore, inhomogeneity corrections should be used in treatment pla...

2003
Patrick N. McDermott Tongming He A. DeYoung

The dose calculation accuracy of a commercial pencil beam IMRT planning system is evaluated by comparison with Monte Carlo calculations and measurements in an anthropomorphic phantom. The target volume is in the right lung and mediastinum and thus significant tissue inhomogeneities are present. The Monte Carlo code is an adaptation of the MCNP code and the measurements were made with TLD and fi...

Journal: :iranian journal of science and technology (sciences) 2008
m. r eskandari

the ionization effects of charged particles produced in neutron interactions for boron neutroncapture therapy are considered here using srim monte carlo code. the estimated values of these effects ina plexiglas acrylic phantom are shown to agree well with the available experimental values in high boronconcentration areas. as expected, the ionization effects from lithium and alpha particles are ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید