background: two protocols of aapm tg-51 and iaea trs-398 were compared followed by a measurement and monte carlo simulation of beam quality correction factor, kq, aapm tg-51 and iaea trs-398 protocols were compared for the absorbed dose to water for dw, and kq parameters. materials and methods: dose measurements by either protocols were performed with cylindrical and plane parallel chambers for...
In order to increase the usefulness of the alanine dosimeter as a tool for quality assurance measurements in radiotherapy using MV x-rays, the response with respect to the dose to water needs to be known accurately. This quantity is determined experimentally relative to (60)Co for 4, 6, 8, 10, 15 and 25 MV x-rays from two clinical accelerators. For the calibration, kQ factors for ionization cha...
INTRODUCTION AND PURPOSE Conventional x-ray films and radiochromic films have inherent challenges for high precision radiotherapy dosimetry. Here we have investigated basic characteristics of optically stimulated luminescence (OSL) of irradiated films containing carbon-doped aluminum oxide (Al2O3:C) for dosimetry in therapeutic photon and electron beams. MATERIALS AND METHODS The OSL films co...
Astrophysical neutron capture rates of light and heavy nuclei have been measured and calculated. For the measurements the activation technique was applied at the 3.75 MV Karlsruhe Van de Graaff accelerator, and at the Geel electron linear accelerator (GELINA) the time–of–flight (TOF) method was used. The calculations were performed using direct and compound nuclear capture models.
Effect of an integral quality monitor on 4‐, 6‐, 10‐MV, and 6‐MV flattening filter‐free photon beams
The accurate measurement of the linear accelerator (linac) radiation isocenter is critical, especially for stereotactic treatment. Traditional quality assurance (QA) procedure focuses on the measurement of single radiation isocenter, usually of 6 megavoltage (MV) photon beams. Single radiation isocenter is also commonly assumed in treatment planning systems (TPS). Due to different flattening fi...
INTRODUCTION Correct target positioning is crucial for accurate dose delivery in breast radiotherapy resulting in utilisation of daily imaging. However, the radiation dose from daily imaging is associated with increased probability of secondary induced cancer. The aim of this study was to quantify doses associated with three imaging modalities and investigate the correlation of dose and varying...
A Monte Carlo model of an Elekta Precise linear accelerator has been built and verified by measured data for a 6 and 10 MV photon beam running with and without a flattening filter in the beam line. In this study the flattening filter was replaced with a 6 mm thick copper plate, provided by the linac vendor, in order to stabilize the beam. Several studies have shown that removal of the filter im...
Highly attenuating radiation treatment couches are no longer useful in the present era of radiotherapy utilizing IMRT and IGRT. Carbon fibers couch tops with its high tensile strength and low density present a useful alternative. The objective of the current study was to quantify the attenuation of megavoltage photons through a Brainlab imaging couch top and headrest at various angles and field...
Cone-beam digital tomosynthesis (CBDT) is a new approach that was recently proposed for rapid tomographic imaging of soft-tissue targets in the radiotherapy treatment room. One of the potential problems in implementing CBDT using, for example, megavoltage (MV) X rays is the possibility of artifacts caused by image lag and ghosting of the X-ray detector used. In the present work, we developed a ...