نتایج جستجو برای: 201l stainless steel
تعداد نتایج: 83347 فیلتر نتایج به سال:
the microstructure of hp stainless steel in aged and aged + solution annealed conditions and solutionized alloy 800 was characterized by optical microscopy, scanning electron microscopy (sem), and transmission electron microscopy (tem) equipped by eds. all phases present in the above condition were described. the effects of solution annealing heat treatment temperature on the microstructure, te...
Allegheny Ludlum Type 316Ti (UNS S31635) is a titanium stabilized version of Type 316 molybdenum-bearing austenitic stainless steel. It is also known as DIN/EN designation No. 1.4571. The Type 316 alloys are more resistant to general corrosion and pitting/crevice corrosion than the conventional chromium-nickel austenitic stainless steels such as Type 304. They also offer higher creep, stress-ru...
A general method for brazing ceramics to metals using a compliant metallic foam as a buffer layer has been developed. Using stainless steel foams, bonds between alumina and 316 stainless steel with shear strengths up to 33 MPa have been achieved. The resultant ductility enhances the resistance of the joint to thermal cycling; AlN-Inconel 600 bonds exhibited good thermal shock resistance. Alumin...
Stainless steel and graphite electrodes were individually addressed and polarized at −0.60 V vs. Ag/AgCl in reactors filled with a growth medium that contained 25 mM fumarate as the electron acceptor and no electron donor, in order to force the microbial cells to use the electrode as electron source. When the reactor was inoculated with Geobacter sulfurreducens, the current increased and stabil...
The adhesion of the solids presents in food can difficult the process of surface cleaning and promotes the bacterial adhesion process and can trigger health problems. In our study, we used UHT whole milk, chocolate based milk and infant formula to evaluate the adhesion of Enterobacter sakazakii on stainless steel coupons, and we determine the work of adhesion by measuring the contact angle as w...
AIM To evaluate root canal transportation at the major foramen through the use of stainless steel size 08 K-Flex files, size 10 reamers, and XF finger spreaders when used as patency instruments. METHODOLOGY One hundred and two mesiobuccal canals of maxillary and mandibular first molars were randomly divided into three groups (34 canals each). Size 08 stainless steel K-Flex files, size 10 stai...
PURPOSE Vertical root fracture (VRF) is a common complication in endodontically treated teeth. Considering the poor prognosis of VRF, a reliable and valid detection method is necessary. Cone beam computed tomography (CBCT) has been reported to be a reliable tool for the detection of VRF; however, the presence of metallic intracanal posts can decrease the diagnostic values of CBCT systems. This ...
BACKGROUND AND PURPOSE Gold has often been used in medicine because of its radiopacity and flexibility. To perform stent-supported coil embolization of intracranial aneurysms, we prepared a gold stent and examined its flexibility, radiopacity, and thrombogenic properties in comparison with a stainless steel device implanted in vitro and in vivo. METHODS Gold stents were prepared by plating go...
OBJECTIVE To compare biomechanical stiffness of cadaveric canine cervical spine constructs stabilized with bicortical stainless steel pins and polymethylmethacrylate (PMMA), monocortical stainless steel screws with PMMA, or monocortical titanium screws with PMMA. STUDY DESIGN Biomechanical cadaver study. ANIMALS Eighteen canine cervical vertebral columns (C2-C7) were collected from skeletal...
Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern?
BACKGROUND CONTEXT Surgeons are hesitant to mix components made of differing metal classes for fear of galvanic corrosion complications. However, in vitro studies have failed to show a significant potential for galvanic corrosion between titanium and stainless steel, the two primary metallic alloys used for spinal implants. Galvanic corrosion resulting from metal mixing has not been described i...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید