نتایج جستجو برای: 2 ایمپلانت تیتانیومی ti6al4v

تعداد نتایج: 2526880  

Journal: :Surface & Coatings Technology 2021

In this paper an effect of capsule-free hot isostatic pressing (HIP) on the porosity and mechanical properties different cold spray deposits was experimentally evaluated. The HIP post-treatment significantly decreased (more than 2 times) 316L pure titanium deposits. densification porous Ti6Al4V deposit less pronounced. Mechanical after were also improved. particular, tensile strength stainless ...

هدف از این پژوهش، اعمال پوشش هاردستونایت (Ca2ZnSi2O7) به روش لایه نشانی الکتروفورتیک روی زیر لایه تیتانیومی (Ti-6Al-4V) بود. ابتدا هاردستونایت به روش سل-ژل تهیه گردید. ساختار، شکل و آنالیز عنصری پودر تولید شده، به کمک میکروسکوپ الکترونی روبشی (SEM)، میکروسکوپ الکترونی عبوری (TEM)، پراش پرتو ایکس (XRD) و طیف سنج توزیع انرژی پرتو ایکس (EDAX) بررسی شد. سمیت نانوذرا...

2016
Zhentao Man Dan Sha Shui Sun Tao Li Bin Li Guang Yang Laibo Zhang Changshun Wu Peng Jiang Xiaojuan Han Wei Li

Total hip arthroplasty (THA) is a common procedure for the treatment of end-stage hip joint disease, and the demand for revision THA will double by 2026. Ti6Al4V (Titanium, 6% Aluminum, and 4% Vanadium) is a kind of alloy commonly used to make hip prothesis. To promote the osseointegration between the prothesis and host bone is very important for the revision THA. The peptide Arg-Gly-Asp (RGD) ...

2016
Shahab Ahmadi Iman Mohammadi S. K. Sadrnezhaad

Article history: Received 17 July 2015 Revised 18 December 2015 Accepted in revised form 19 December 2015 Available online 21 December 2015 The main challenges of biological implants are suitable strength, adhesion, biocompatibility and corrosion resistance. This paper discusses fabrication, characterization and electrochemical investigation of anodized Ti6Al4V without and with a hydroxyapatite...

2014
Eun-Ju Oh Thuy-Duong T. Nguyen Seung-Youp Lee Young-Mi Jeon Tae-Sung Bae Jong-Gee Kim

OBJECTIVE To evaluate the bioactivity, and the biomechanical and bone-regenerative properties of Ti6Al4V miniscrews subjected to anodization, cyclic precalcification, and heat treatment (APH treatment) and their potential clinical use. METHODS The surfaces of Ti6Al4V alloys were modified by APH treatment. Bioactivity was assessed after immersion in simulated body fluid for 3 days. The hydroph...

2014
T. Halim I. C. Clarke M. D. Burgett-Moreno T. K. Donaldson C. Savisaar J. G. Bowsher

OBJECTIVES Third-body wear is believed to be one trigger for adverse results with metal-on-metal (MOM) bearings. Impingement and subluxation may release metal particles from MOM replacements. We therefore challenged MOM bearings with relevant debris types of cobalt-chrome alloy (CoCr), titanium alloy (Ti6Al4V) and polymethylmethacrylate bone cement (PMMA). METHODS Cement flakes (PMMA), CoCr a...

Journal: :Biomaterials 2016
Jordan Raphel Johan Karlsson Silvia Galli Ann Wennerberg Christopher Lindsay Matthew G Haugh Jukka Pajarinen Stuart B Goodman Ryo Jimbo Martin Andersson Sarah C Heilshorn

Here we present the design of an engineered, elastin-like protein (ELP) that is chemically modified to enable stable coatings on the surfaces of titanium-based dental and orthopaedic implants by novel photocrosslinking and solution processing steps. The ELP includes an extended RGD sequence to confer bio-signaling and an elastin-like sequence for mechanical stability. ELP thin films were fabric...

2017
M A K Chowdhury A M M Sharif Ullah Saqib Anwar

Ti6Al4V alloys are difficult-to-cut materials that have extensive applications in the automotive and aerospace industry. A great deal of effort has been made to develop and improve the machining operations of Ti6Al4V alloys. This paper presents an experimental study that systematically analyzes the effects of the machining conditions (ultrasonic power, feed rate, spindle speed, and tool diamete...

2015
Carolin Gabler Carmen Zietz Richard Bieck Rebecca Göhler Tobias Lindner Maximilian Haenle Birgit Finke Jürgen Meichsner Holger Testrich Mathias Nowottnick Bernhard Frerich Rainer Bader

A common method to derive both qualitative and quantitative data to evaluate osseointegration of implants is histomorphometry. The present study describes a new image reconstruction algorithm comparing the results of bone-to-implant contact (BIC) evaluated by means of µCT with histomorphometry data. Custom-made conical titanium alloyed (Ti6Al4V) implants were inserted in the distal tibial bone ...

2012
F. Billi E. Onofre E. Ebramzadeh T. Palacios ML Escudero MC Garcia-Alonso

Fretting wear and corrosion of Ti6Al4V alloys at the bone/implant stem interface produces the release of wear particles and corrosive ions from the stem into the surrounding tissue that can induce bone resorption. In this work, oxidation treatments at 500o and 700 oC for 1 h have been studied for increasing the friction-corrosion resistance at these interfaces. The friction-corrosion process of...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید