نتایج جستجو برای: نانوکامپوزیت زمینه ti6al4v

تعداد نتایج: 114994  

2016
Shahab Ahmadi Iman Mohammadi S. K. Sadrnezhaad

Article history: Received 17 July 2015 Revised 18 December 2015 Accepted in revised form 19 December 2015 Available online 21 December 2015 The main challenges of biological implants are suitable strength, adhesion, biocompatibility and corrosion resistance. This paper discusses fabrication, characterization and electrochemical investigation of anodized Ti6Al4V without and with a hydroxyapatite...

2014
Eun-Ju Oh Thuy-Duong T. Nguyen Seung-Youp Lee Young-Mi Jeon Tae-Sung Bae Jong-Gee Kim

OBJECTIVE To evaluate the bioactivity, and the biomechanical and bone-regenerative properties of Ti6Al4V miniscrews subjected to anodization, cyclic precalcification, and heat treatment (APH treatment) and their potential clinical use. METHODS The surfaces of Ti6Al4V alloys were modified by APH treatment. Bioactivity was assessed after immersion in simulated body fluid for 3 days. The hydroph...

2014
T. Halim I. C. Clarke M. D. Burgett-Moreno T. K. Donaldson C. Savisaar J. G. Bowsher

OBJECTIVES Third-body wear is believed to be one trigger for adverse results with metal-on-metal (MOM) bearings. Impingement and subluxation may release metal particles from MOM replacements. We therefore challenged MOM bearings with relevant debris types of cobalt-chrome alloy (CoCr), titanium alloy (Ti6Al4V) and polymethylmethacrylate bone cement (PMMA). METHODS Cement flakes (PMMA), CoCr a...

Journal: :Biomaterials 2016
Jordan Raphel Johan Karlsson Silvia Galli Ann Wennerberg Christopher Lindsay Matthew G Haugh Jukka Pajarinen Stuart B Goodman Ryo Jimbo Martin Andersson Sarah C Heilshorn

Here we present the design of an engineered, elastin-like protein (ELP) that is chemically modified to enable stable coatings on the surfaces of titanium-based dental and orthopaedic implants by novel photocrosslinking and solution processing steps. The ELP includes an extended RGD sequence to confer bio-signaling and an elastin-like sequence for mechanical stability. ELP thin films were fabric...

2017
M A K Chowdhury A M M Sharif Ullah Saqib Anwar

Ti6Al4V alloys are difficult-to-cut materials that have extensive applications in the automotive and aerospace industry. A great deal of effort has been made to develop and improve the machining operations of Ti6Al4V alloys. This paper presents an experimental study that systematically analyzes the effects of the machining conditions (ultrasonic power, feed rate, spindle speed, and tool diamete...

2015
Carolin Gabler Carmen Zietz Richard Bieck Rebecca Göhler Tobias Lindner Maximilian Haenle Birgit Finke Jürgen Meichsner Holger Testrich Mathias Nowottnick Bernhard Frerich Rainer Bader

A common method to derive both qualitative and quantitative data to evaluate osseointegration of implants is histomorphometry. The present study describes a new image reconstruction algorithm comparing the results of bone-to-implant contact (BIC) evaluated by means of µCT with histomorphometry data. Custom-made conical titanium alloyed (Ti6Al4V) implants were inserted in the distal tibial bone ...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه ارومیه - دانشکده فنی 1392

توربین های گازی به لحاظ مزایای بیشمار و کاربرد بسیار وسیع آنها در صنایع مختلف ، به عنوان یک صنعت با تکنولوژی بالا توجه دانشمندان و محققان بسیاری را به خود جلب نموده و همه روزه شاهد پیشرفتهای مختلف در زمینه بالا بردن راندمان و افزایش قدرت و کاربرد گسترده این توربین ها میباشیم. عمده این موفقیتها به دلیل پیشرفتهای مهم در علوم مواد و فرایندهای تولید در سی سال گذشته میباشد. از جمله آلیاژی که برای پر...

2012
F. Billi E. Onofre E. Ebramzadeh T. Palacios ML Escudero MC Garcia-Alonso

Fretting wear and corrosion of Ti6Al4V alloys at the bone/implant stem interface produces the release of wear particles and corrosive ions from the stem into the surrounding tissue that can induce bone resorption. In this work, oxidation treatments at 500o and 700 oC for 1 h have been studied for increasing the friction-corrosion resistance at these interfaces. The friction-corrosion process of...

Journal: :International journal of molecular medicine 2013
Yongyuan Guo Desheng Chen Mengqi Cheng Weijie Lu Liqiang Wang Xianlong Zhang

Titanium (Ti) alloys of the β-type are highly attractive metallic materials for biomedical applications due to their low elastic modulus, high corrosion resistance and notable biocompatibility. A new β-type Ti35Nb2Ta3Zr alloy with a low Young's modulus of approximately 48 GPa was previously fabricated. In the present study, the biocompatibility of...

ژورنال: نانو مواد 2014
حمزه شاهرجبیان محمدرضا دشت بیاض

در این تحقیق خواص مکانیکی نانوکامپوزیت زمینه اپوکسی پر شده با ذرات نانومتری آلومینا مورد بررسی قرار گرفته است. رزین اپوکسی و ذرات آلومینا توسط یک همزن برشی با یکدیگر مخلوط گردیده و نانوکامپوزیت‌های با 2، 5 و 8 درصد کسر وزنی آلومینا تولید شده‌اند. برای بررسی خواص مکانیکی نانوکامپوزیت، نمونه‌های استاندارد آزمایش‌های کشش و ضربه چارپی تهیه گردیده‌اند. نتایج آزمایش‌های مکانیکی نشان داده است که با اف...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید