نتایج جستجو برای: x ray protection

تعداد نتایج: 838645  

Journal: :journal of medical signals and sensors 0
fatemeh ghofrani mohammad sadegh helfroush mahmoud rashidpour kamran kazemi

in this paper a novel fuzzy scheme for medical x-ray image classification is presented. in this method, any image is partitioned in to 25 overlapping subimages and then shape-texture features are extracted from shape and directional information extracted from any subimage. in the classification stage, we apply a fuzzy membership to any subimage with respect to euclidean distance between feature...

Journal: :Radiologic technology 2008
Lois Lehman

Lois Lehman, R.T.(R)(CT), is assistant director of radiology at Texas Scottish Rite Hospital for Children in Dallas. Radiographers understand the importance of getting the most diagnostic information from as few radiographs as possible. And in the world of pediatric scoliosis imaging, pediatric orthopedic surgeons, radiologists and orthotists must obtain more than just spine data from each and ...

Journal: :journal of biomedical physics and engineering 0
m kazempoor 1. msc, department of radiobiology, school of paramedical sciences, shiraz university of medical sciences, shiraz, iran; 2. student research committee, school of paramedical sciences, shiraz university of medical sciences, shiraz, iran; m saeedimoghadam ionizing and non-ionizing radiation protection research center, school of paramedical sciences, shiraz university of medical sciences, shiraz, iran f shekoohi shooli n shokrpoor english department, faculty of paramedical sciences, shiraz university of medical sciences, shiraz, iran

background: in diagnostic radiology lead apron, are usually used to protect patients and radiology staff against ionizing radiation. lead apron is a desirable shield due to high absorption and effective attenuation of x-ray photons in the diagnostic radiology range. objective: although lead aprons have good radiation protection properties, in recent years, researchers have been looking for alte...

Journal: :journal of medical education 0
m r tavakoli

background: the use of the ionizing radiation in the medical practice has evolved since its beginnings. their benefit for the patient is considerable in term of comfort, diagnostic and therapeutic effectiveness. it is estimated that 30% to 50% of critical decisions in medical approaches is based on x-ray examination. using the x-ray as a diagnostic means by clinicians requires appropriate and a...

Journal: :Medical physics 2012
J P McCaffrey F Tessier H Shen

PURPOSE To measure the attenuation effectiveness and minimize the weight of new non-Pb radiation shielding materials used for radiation protection by interventional radiology (IR) physicians, to compare the accuracy of the different standard measurement geometries of these materials, and to determine x-ray qualities that correspond to the scattered radiation that IR physicians typically encount...

Elham Piruzan Mehdi Zehtabian, Sedigheh Sina Zahra Molaiemanesh,

Introduction Lead-based shields are the most widely used attenuators in X-ray and gamma ray fields. The heavy weight, toxicity and corrosion of lead have led researchers towards the development of non-lead shields. Materials and Methods The purpose of this study was to design multi-layered shields for protection against X-rays and gamma rays in diagnostic radiology and nuclear medicine. In this...

Ali Mahmoud- Pashazadeh Behrouz Rasuli, Jafar Fatahi-Asl Mohamad Javad Tahmasebi Birgani, Mohammad Ghorbani Mozafar Naserpour

Introduction Quality control techniques used to test the components of the radiological system and verify that the equipment is operating satisfactorily. In this study, quality control (QC) assessment of conventional radiology devices was performed in frequently visited radiology centers of Khuzestan province, Iran. Materials and Methods Fifteen conventional radiology devices were examined, bas...

Fatemeh Seif, Ghasem Habibi Hadi Ansarihadipour Mohamad Reza Bayatiani,

Introduction: Exposure to ionizing radiation can be through direct hit or water radiolysis lead to oxidation in biological systems. In this study, the protective effect of Myrtus Communis aqueous extract on structural changes and oxidative stress in red blood cells and plasma proteins was examined after receipt of ionizing radiation. Materials and Methods: wis...

2011
Konstantin Ignatyev Peter R.T. Munro Deeph Chana Robert D. Speller Alessandro Olivo

X-ray baggage scanners play a basic role in the protection of airports, customs, and other strategically important buildings and infrastructures. The current technology of baggage scanners is based on x-ray attenuation, meaning that the detection of threat objects relies on how various objects differently attenuate the x-ray beams going through them. This capability is enhanced by the use of du...

Journal: :Japanese Journal of Radiological Technology 1974

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید