نتایج جستجو برای: visante
تعداد نتایج: 76 فیلتر نتایج به سال:
BACKGROUND/AIMS To preliminarily evaluate the repeatability of central corneal thickness (CCT) measurements performed with Anterior Segment Optical Coherence Tomography (AS-OCT) on eye bank posterior corneal lenticules. METHODS Six donor lenticules were created with a 350 μm head microkeratome (Moria, Antony, France). All donor tissues were stored at 4°C in Eusol-C solution (Alchimia S.r.l, P...
Purpose. Application of anterior segment optical coherence (AS-OCT) in pediatric ophthalmology. Methods. Retrospective clinical study case series of 26 eyes of 19 pediatric patients throughout a 21-month period, presenting anterior segment pathologies, were submitted to AS-OCT examination (OCT Visante, 1310 nm, Zeiss), noncontact technique, no sedation requirement. Results. AS-OCT images were o...
In recent years, the rapid development of diagnostic optic devices has generated optical coherence tomography (OCT) as a new, non-invasive diagnostic method. With technical progress of the infrared spectrum at 1,310 nm, OCT of the anterior segment also became feasible. With anterior segment OCT different examinations which so far were ruled out by ultrasound in contact manner could be executed ...
PURPOSE To describe the preparation and thickness profiles of endothelial keratoplasty lenticules harvested from eyes with previous photorefractive keratectomy (PRK). METHODS Donor whole eyes that underwent PRK were subjected to microkeratome-assisted dissection for Descemet stripping automated endothelial keratoplasty. Specular microscopy and Visante optical coherence tomography were perform...
Background The purpose of this prospective, randomised study was to interocularly compare the visual performance after implantation of two different toric IOLs with different haptic design. Methods 59 subjects with corneal astigmatism greater than 1.25 diopter (D) were implanted with an AT TORBI 709M IOL (Carl Zeiss Meditec AG) in one eye and with a Tecnis toric aspheric IOL (Abbot Medical Op...
PURPOSE To assess and compare the morphology of laser in situ keratomileusis flaps (LASIK) created by a 60 kHz femtosecond laser and a mechanical microkeratome. SETTING Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany. METHODS Anterior segment optical coherence tomography (AS-OCT) (Visante) was used to assess 1 week postoperatively the morphology of...
PURPOSE To describe the technique of deep sclerectomy with the new Esnoper-Clip® implant, the clinical outcome and the anatomic characteristics of filtering blebs, using anterior segment optical coherence tomography (AS-OCT). METHODS A prospective case-series study was conducted in five eyes (5 patients) with open angle glaucoma. The fornix-based deep sclerectomy with Esnoper-Clip® implant wa...
To measure the corneal thickness and the depth of the precorneal tear film of contact lens wearers with keratoconus or keratoplasty and to reconfirm the identification and classification of the keratoconus with optical coherence tomography (OCT). The cornea and precorneal tear film of 123 eyes with keratoconus, of 39 eyes after keratoplasty and 8 eyes after LASIK were examined with an OCT (Zeis...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید