F. Haryanto, I. Arif, M.F. Rhani, R.C.X. Soh, S. Yani,

Background: The lack of lateral electronic disequilibrium (LED) becomes a main problem in small field. This factor affects the dose in target volume cannot predict correctly. In addition, utilization of high-energy linear accelerator (10 MV) can emit some unwanted particles (electron contamination). Therefore, the aim of this study was to characterize head linear accelerator (linac) Varian Clin...

Journal: :Medical physics 2016
Z Saleh X Tang Y Song C Obcemea N Beeban M Chan X Li G Tang S Lim D Lovelock T LoSasso J Mechalakos S Both

PURPOSE To investigate the long term stability and viability of using EPID-based daily output QA via in-house and vendor driven protocol, to replace conventional QA tools and improve QA efficiency. METHODS Two Varian TrueBeam machines (TB1&TB2) equipped with electronic portal imaging devices (EPID) were employed in this study. Both machines were calibrated per TG-51 and used clinically since ...

2014
Song Gao Weiliang Du Peter Balter Peter Munro Andrew Jeung

The purpose of this study is to evaluate the accuracy and reproducibility of the IsoCal geometric calibration system for kilovoltage (kV) and megavoltage (MV) imagers on Varian C-series linear accelerators (linacs). IsoCal calibration starts by imaging a phantom and collimator plate using MV images with different collimator angles, as well as MV and kV images at different gantry angles. The sof...

Journal: :Medical physics 2012
H Van Herck W Crijns P Slagmolen F Maes F Van den Heuvel K Haustermans

PURPOSE To automatically detect intrafraction motion during arc radiotherapy for prostate cancer patients by tracking fiducial markers in two-dimensional MV images acquired using the treatment beam, in order to adjust radiation dose accordingly. METHODS Four fiducial gold markers are implanted in a patient's prostate. Patients are irradiated using a Varian Linac 2100 C/D with RapidArc upgrade...

Journal: :Proceedings 2017
Luis Alberto Vazquez-Quino Claudia Ivette Huerta-Hernandez Dharanipathy Rangaraj

Mobius FX, an add-on software module from Mobius Medical Systems™ for intensity-modulated radiation therapy (IMRT) quality assurance (QA), uses linac treatment logs to efficiently calculate and verify the 3D dose delivered to patients. An advantage of the Mobius FX module is that it does not require device positioning. In this study, we compared the Mobius FX with another QA option, ArcCheck, a...

2004
Gary A. Ezzell

We have recently commissioned a temporary radiation therapy facility that is novel in two aspects: it was constructed using modular components, and the LINAC was installed in one of the modular sections before it was lifted into position. Additional steel and granular fill was added to the modular sections on-site during construction. The building will be disassembled and removed when no longer...

Journal: :Radiological physics and technology 2015
Genichiro Wakabayashi Akihiro Nohtomi Eriko Yahiro Toshioh Fujibuchi Junichi Fukunaga Yoshiyuki Umezu Yasuhiko Nakamura Katsumasa Nakamura Makoto Hosono Tetsuo Itoh

The applicability of the activation of an NaI scintillator for neutron monitoring at a clinical linac was investigated experimentally. Thermal neutron fluence rates are derived by measurement of the I-128 activity generated in an NaI scintillator irradiated by neutrons; β-rays from I-128 are detected efficiently by the NaI scintillator. In order to verify the validity of this method for neutron...

2014
James Kwame Annkah Ivan Rosenberg Naina Hindocha Syed Ali Moinuddin Kate Ricketts Abiodun Adeyemi Gary Royle

The dosimetric accuracies of CATPhan 504 and CIRS 062 have been evaluated using the kV-CBCT of Varian TrueBeam linac and Eclipse TPS. The assessment was done using the kV-CBCT as a standalone tool for dosimetric calculations towards Adaptive replanning. Dosimetric calculations were made without altering the HU-ED curves of the planning computed tomography (CT) scanner that is used by the Eclips...

Journal: :Medical physics 2012
A Keyvanloo B Burke B Warkentin T Tadic S Rathee C Kirkby D M Santos B G Fallone

PURPOSE The magnetic fields of linac-MR systems modify the path of contaminant electrons in photon beams, which alters patient skin dose. To accurately quantify the magnitude of changes in skin dose, the authors use Monte Carlo calculations that incorporate realistic 3D magnetic field models of longitudinal and transverse linac-MR systems. METHODS Finite element method (FEM) is used to genera...