نتایج جستجو برای: uncemented
تعداد نتایج: 1047 فیلتر نتایج به سال:
A 62-year-old man presented with the acute, atraumatic onset of pain 3 years after uncemented right total knee arthroplasty. He complained of new mechanical locking with the knee held in extension on examination and unable to flex the knee. On the plain radiographs, the patellar component peg was fractured and the plate was dislocated. The knee was immobilized, and revision to a cemented 3-peg ...
PURPOSE To examine the frequency of technical errors during implantation of the Austin Moore prosthesis in a public hospital. METHODS Radiographs and charts of 147 consecutive uncemented Austin Moore hemiarthoplasty patients were retrospectively reviewed with particular reference to intra-operative errors associated with early failure of the prosthesis. RESULTS 48% of the patients had at le...
We studied the effect of a layer of cement placed under the tibial component of Freeman-Samuelson total knee prostheses with a metal back and an 80 mm intramedullary stem, using roentgen stereophotogrammetry to measure the migration of the tibial component during one year in 13 uncemented and 16 cemented knees. The addition of cement produced a significant reduction in migration at one year, fr...
Revisions of fractured, uncemented and extensively porous-coated femoral stems are challenging. In this article, we report three cases of revision surgeries for broken, cementless, and extensively porous-coated femoral stems with Solution stems (DePuy, Warsaw, Indiana). In all cases, minimally invasive endofemoral revision was successfully performed without femoral osteotomy or cortical fenestr...
We present a hybrid multivariate calibration method, constrained regularization (CR), and demonstrate its utility via numerical simulations and experimental Raman spectra. In this new method, multivariate calibration is treated as an inverse problem in which an optimal balance between model complexity and noise rejection is achieved with the inclusion of prior information in the form of a spect...
Our aim was to determine the precision of the measurements of bone mineral density (BMD) by dual-energy x-ray absorptiometry in the proximal femur before and after implantation of an uncemented implant, with particular regard to the significance of retro- and prospective studies. We examined 60 patients to determine the difference in preoperative BMD between osteoarthritic and healthy hips. The...
This article reports a case of bilateral fatigue fracture of the femoral components in a cruciate-retaining uncemented total knee arthroplasty (TKA). A 75-year-old woman (height, 158 cm; weight, 72 kg; body mass index, 29.2) had undergone one-stage bilateral TKA for osteoarthritis 11 years previously at the author's institution. Surgery was performed using an uncemented Flexible Nichidai Knee. ...
Peri-prosthetic femoral fracture after total hip replacement (THR) is associated with a poor outcome and high mortality. However, little is known about its long-term incidence after uncemented THR. We retrospectively reviewed a consecutive series of 326 patients (354 hips) who had received a CLS Spotorno replacement with an uncemented, straight, collarless tapered titanium stem between January ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید