نتایج جستجو برای: treatment couch

تعداد نتایج: 1395060  

2017
Amy Yu Benjamin Fahimian Lynn Million Annie Hsu

Purpose  Radiotherapy treatment planning of extended volume typically necessitates the utilization of multiple field isocenters and abutting dosimetrically matched fields in order to enable coverage beyond the field size limits. A common example includes total lymphoid irradiation (TLI) treatments, which are conventionally planned using dosimetric matching of the mantle, para-aortic/spleen, and...

Journal: :Journal of Applied Clinical Medical Physics 2005

2012
Vincent Althof Paul van Haaren Rik Westendorp Tonnis Nuver Dinant Kramer Marijke Ikink Arjen Bel Andre Minken

The purpose of this study was to develop and evaluate filmless quality assurance (QA) tools for helical tomotherapy by using the signals from the on-board megavoltage computed tomography (MVCT) detector and applying a dedicated step-wedge phantom. The step-wedge phantom is a 15 cm long step-like aluminum block positioned on the couch. The phantom was moved through the slit beam and MVCT detecto...

2017
Alexander Jöhl Marta Bogowicz Stefanie Ehrbar Matthias Guckenberger Stephan Klöck Mirko Meboldt Oliver Riesterer Melanie Zeilinger Marianne Schmid Daners Stephanie Tanadini-Lang

BACKGROUND Intrafractional motion can be a substantial uncertainty in precision radiotherapy. Conventionally, the target volume is expanded to account for the motion. Couch-tracking is an alternative, where the patient is moved to compensate for the tumor motion. However, the couch motion may influence the patient's stress and respiration behavior decreasing the couch-tracking effectiveness. ...

Journal: :Film Criticism 2015

Journal: :MRS Bulletin 1990

2009
Ruijie Rachel Liu Karl Prado Michael Gillin

For most computed tomography (CT) simulators, radiation therapists must remove the flat couch top to perform daily CT quality assurance (QA), and then use separate tools to perform localization-laser QA. This process wastes time and effort and creates the opportunity for accidents to occur. In this study, we tested a simple yet comprehensive daily QA program and phantom that we designed for CT ...

2008
Alvaro Obregon

We look at the problem of real-time tumor tracking and motion compensation in radiotherapy techniques from a pure feedback-control point of view and try to understand it using simple mechanical models of the treatment couch and breathing patterns. Since we want to control a robotic couch based on the data collected in real-time, we propose the use of an acceleration sensor to develop a feedback...

2017
Jasmine A. Oliver Patrick Kelly Sanford L. Meeks Twyla R. Willoughby Amish P. Shah

Purpose To characterize the accuracy of noncoplanar image guided radiation therapy with the Varian Edge radiosurgery system for intracranial stereotactic radiosurgery (SRS) treatments by assessing the accuracy of kV/kV orthogonal pair registration with Optical Surface Monitoring System (OSMS) monitoring relative to cone beam computed tomography (CT). Methods and materials A Computerized Imagi...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید