نتایج جستجو برای: transformer wtt

تعداد نتایج: 11586  

In this paper, a new model based on the thevenin equivalent circuit for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the transformer is considered. The ultra-saturation phenomenon causes the mal-operation of the power transformer differential protection. So, the description a...

2005
Pat Bodger

An overview of the research and developments into new transformer design, undertaken in the Department of Electrical and Computer Engineering, University of Canterbury, is presented. Initially, single phase, 50 Hz, l1/0.23kV pole mount distribution transformers were fitted with either silicon or amorphous steel cores. The transformer tanks were filled with either standard transformer oil or liq...

2013
Mohammed Abdul Rahman Uzair Mohammed Mohiuddin Mohammed Khaja Shujauddin

This paper deals with three types of power transformer failure analysis tests which can help in monitoring the transformer condition. The three methods are Conventional oil test, Furan derivatives test and Markov models criteria. Conventional oil testing procedure includes determination of gas concentrations in the transformer oil sample and analyzing the fault by considering ratio of two suita...

One of transient phenomenon that causes the mal-operation of the power transformer differential protection during the energization of a loaded power transformer is the ultra-saturation phenomenon. In this paper, a new model for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the pow...

2009
Sy-Ruen Huang Chin-Wen Liao Hong-Tai Chen Chueh-Cheng Wu C.-C. WU

This paper proposes a new method to detect transformer inside incipient fault current using transformer internal parameters to determine the inside structure of transformer at good condition or bad. A transformer model was established by Jiles– Atherton theory using measured voltage and current and the initial parameters which were found using Genetic Algorithm (GA). Then, transformer internal ...

Journal: :Science of The Total Environment 2021

This research assesses the well-to-tank (WTT) greenhouse gas (GHG) emissions and economic performance of an innovative bio-jet fuel via acetone-butanol-ethanol (ABE) fermentation. Dutch potato by-products from food processing industry sugar beets are explored as potential feedstocks. Four product systems differentiated by feedstocks, logistics centralized/decentralized fermenters investigated. ...

2014
Geetha Mani

In transformer fault diagnosis, dissolved gas analysis (DGA) is been widely employed for a long period and numerous methods have been innovated to interpret its results. Still in some cases it fails to identify the corresponding faults. Due to the limitation of training data and non-linearity, the estimation of key-gas ratio in the transformer oil becomes more complicated. This paper presents I...

جلیلیان, علیرضا , عبداللهی, روح اله ,

In this paper, a 24-pulse ac-dc converter is designed, modeled and simulated based on a fork autotransformer to improve power quality indices. The use of autotransformer results in reduced kVA rating of the proposed topology as compared with the transformer based 24-pulse converter. Due to the proper flexibility of the proposed topology, it can be simply utilized in other similar applications. ...

Journal: :journal of artificial intelligence in electrical engineering 0

in this article, a multi-objective function for placement of distributed generation (dg) and capacitors with thetap setting of under load tap changer (ultc) transformer is introduced. most of the recent articles have paidless attention to dg, capacitor placement and ultc effects in the distribution network simultaneously. insimulations, a comparison between different modes was carried out with,...

2006
Zhang Weizheng Li Yanming Yang Lanjun

This paper presents the general knowledge, theory and methodology of life management that used in electric power transformer. The paper also discusses the basic failure theory and method to establish failure model of power transformer. Insulation ageing is a problem due to dielectric, chemical, thermal and electro-mechanic stresses, which is highly depending on operational conditions. Life mana...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید