نتایج جستجو برای: transcutaneous bilirubin measurements
تعداد نتایج: 391618 فیلتر نتایج به سال:
Background: Transcutaneous bilirubin measurement (TcB) is widely used in term babies, but its effectiveness as well the suitable site for preterm babies still debated. Aim and Objective: To compare diagnostic accuracy of different transcutaneous sites with serum total neonate. Methods: This prospective comparative study was carried out special care baby unit at Alwahda teaching hospital-Derna-L...
Evaluation of the neonates for jaundice and kernicterus is indispensable when early hospital discharge has become standard practice. Transcutaneous bilirubin (TcB) measurement is an advantageous option because of its non-invasive nature and the possibility of its use near the patient. The point of care device BiliCheck has been compared in numerous instances to serum bilirubin. However, its cli...
OBJECTIVES To compare transcutaneous bilirubin measurements made using Bilicheck equipment with assays of capillary plasma using the Unistat bilirubinometer (Leica). METHODS Two hundred concomitant assays were performed (transcutaneous and in plasma), and the correlation and level of agreement between them was calculated. An assessment was also made of the influence of birth weight, skin colo...
I read with interest the study by Alsaedi1 on the transcutaneous bilirubin (TcB) measurement in healthy Saudi term newborns. The author addressed that TcB measurement provided accurate estimates of total serum bilirubin (TSB) values and it can be used effectively to screen newborns for significant jaundice.1 I presume that such conclusion ought to be cautiously taken. Apart from 4 limitations a...
The accuracy of transcutaneous bilirubin (TcB) measurements obtained with a Bilicheck device in 70 preterm neonates before phototherapy and during phototherapy from the exposed and unexposed skin of the forehead (under the eye patch) was evaluated by comparing the TcB with the total serum bilirubin (TSB) that was performed within +/- 30 minutes of the TcB measurements. The correlation and propo...
OBJECTIVE The objective of this study was to evaluate the Minolta/Hill-Rom Air-Shields Transcutaneous Jaundice Meter model JM-103. METHODS We studied a convenience sample of 849 newborns > or =35 weeks of gestation in 3 hospitals. These infants had total serum bilirubin (TSB) levels measured on clinical indication, and transcutaneous bilirubin (TcB) levels were obtained within 1 hour of the T...
Objective: To evaluate the relation between transcutaneous bilirubin (TcB) by BiliChek and total serum bilirubin (TSB) in the Chinese neonates compared with another transcutaneous Bilirubinometer (VanHou). Methods: TcB measurements were performed on the forehead by Bilichek and VanHou. Total serum bilirubin (TSB) was determined within 5 minutes after TcB measurement. The correlation and agreeme...
OBJECTIVE To evaluate the effects of massage therapy on transcutaneous bilirubin of stable preterm infants. METHODS The controlled clinical trial was conducted in 2014 at Shahid Hasheminejhad Hospital, Iran, and comprised preterm neonatal children in the neonatal intensive care unit. The newborns were divided into two groups of massage and control via random allocation. The children in the co...
Background: Neonatal jaundice is a very common condition. Serious unconjugated hyperbilirubinemia may result in neurological dysfunction as catastrophic kernicterus. Phototherapy the method of choice treatment hyperbilirubinemia. Aim and objectives: aim study was to assess accuracy transcutaneous bilirubin measurement during phototherapy by using skin patch comparing this with serum at same tim...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید