نتایج جستجو برای: ti 6al 4v alloy

تعداد نتایج: 83441  

2000
Z. Yan P. B. Nagy

Pulsed infrared laser irradiation was used to positively identify small fatigue cracks on the surface of fatigue damaged Ti–6Al–4V specimens. The resulting transient thermoelastic deformation perceptibly changes the opening of partially closed surface cracks without affecting other scatterers, such as surface grooves, corrosion pits, coarse grains, etc. that might hide the fatigue crack from ul...

2018
Yang Qu Shuang Zheng Rongpeng Dong Mingyang Kang Haohan Zhou Dezhi Zhao Jianwu Zhao

To ensure the biomechanical properties of Ti-24Nb-4Zr-8Sn, stress-shielding effects were compared between Ti-24Nb-4Zr-8Sn and Ti-6Al-4V fixation by using a porcine model. Twelve thoracolumbar spines (T12-L5) of 12-month-old male pigs were randomly divided into two groups: Ti-24Nb-4Zr-8Sn (EG, n = 6) and Ti-6Al-4V (RG, n = 6) fixation. Pedicle screw was fixed at the outer edge of L4-5 vertebral ...

2017
Xiaohao Sun Weiwei Zhou Keiko Kikuchi Naoyuki Nomura Akira Kawasaki Hisashi Doi Yusuke Tsutsumi Takao Hanawa

A low magnetic Zr-1Mo alloy was fabricated by a powder bed fusion (PBF) process using a fiber laser. The microstructure, surface morphology, and pore distribution of the as-built Zr-1Mo alloy were observed. Its magnetic susceptibility and Vickers hardness were evaluated by magnetic susceptibility balance and a microindentation tester, respectively. The as-built Zr-1Mo alloy mainly consisted of ...

2014
L. Novakova

Asymmetric incremental sheet forming (AISF) could significantly reduce costs incurred by the fabrication of complex industrial components with a minimal environmental impact. The AISF experiments were carried out on commercially pure titanium (Ti-Gr2), Timetal (15-3-3-3) alloy, and Ti-6Al-4V (Ti-Gr5) alloy. A special testing geometry was used to characterize the titanium alloys properties from ...

Journal: :Acta biomaterialia 2008
Chengtie Wu Yogambha Ramaswamy David Gale Wenrong Yang Keqin Xiao Liangchi Zhang Yongbai Yin Hala Zreiqat

Hydroxyapatite (HAp) is commonly used to coat titanium alloys (Ti-6Al-4V) for orthopedic implants. However, their poor adhesion strength and insufficient long-term stability limit their application. Novel sphene (CaTiSiO5) ceramics possess excellent chemical stability and cytocompatibility. The aim of this study is to use the novel sphene ceramics as coatings for Ti-6Al-4V. The sol-gel method w...

2017
E. Almanza M. J. Pérez N. A. Rodríguez L. E. Murr

The electron beam melting (EBM) is a useful technique for fabricating alloys that are difficult to machine and require expensive tools as well as the presence of inert atmosphere for further treatments. Under vacuum, EBM provides a controlled environment, reducing the drawbacks of the alloys of their processing in a conventional manner and thereby improving their microstructure, which can enhan...

2005
Ying Long Zhou Mitsuo Niinomi Toshikazu Akahori Hisao Fukui Hiroyuki Toda

Corrosion resistance, wear resistance and biocompatibility of the studied Ti–Ta alloys with Ta contents of 10, 30 and 70 mass% together with the currently used metallic biomaterials pure titanium (Ti) and Ti–6Al–4V extra low interstitial (ELI) alloy were investigated for biomedical applications. Corrosion resistance was measured by an anodic polarization test using an automatic potentiostat in ...

2018
Alethea Liens Aurélien Etiemble Pascaline Rivory Sandra Balvay Jean-Marc Pelletier Sandrine Cardinal Damien Fabrègue Hidemi Kato Philippe Steyer Tais Munhoz Jerome Adrien Nicolas Courtois Daniel J Hartmann Jérôme Chevalier

Ti40Zr10Cu36Pd14 Bulk Metallic Glass (BMG) appears very attractive for future biomedical applications thanks to its high glass forming ability, the absence of toxic elements such as Ni, Al or Be and its good mechanical properties. For the first time, a complete and exhaustive characterization of a unique batch of this glassy alloy was performed, together with ISO standard mechanical tests on ma...

2017
Tatsumi NOGUCHI Masayuki HATTORI Masao YOSHINARI

fluoride-containing solutien. Commercially pure titanium (CP-Ti) and six titanium-based alloys were used: Ti-O.15Pd, Ti6Al-4V, Ti-7Nb-6Al, Ti-55Ni, Ti-10Cu, and Ti-20Cr. Two test solutions were prepared fbr immersion of polished titanium and titanium alloys: one consisting of O,2% NaF + O,9% NaCl (pH 3.8 with lactic acid) and the other of O.1 mol/1 H202 + O.9% NaCl (pH 5.5). Following immersion...

Journal: :Acta biomaterialia 2008
S J Li T C Cui Y L Hao R Yang

Due to recent concern about allergic and toxic effects of Ni ions released from TiNi alloy into human body, much attention has been focused on the development of new Ni-free, metastable beta-type biomedical titanium alloys with a reversible phase transformation between the beta phase and the alpha'' martensite. This study investigates the effect of the stress-induced alpha'' martensite on the m...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید