نتایج جستجو برای: tensile bond strength

تعداد نتایج: 281925  

Journal: :Brazilian dental journal 2016
Rafael Leonardo Xediek Consani Tatiane Marinho Atais Bacchi Ricardo Armini Caldas Victor Pinheiro Feitosa Carmem Silvia Pfeifer

The study verified the bond strength in simulated dental restorations of silorane- or methacrylate-based composites repaired with methacrylate-based composite. Methacrylate- (P60) or silorane-based (P90) composites were used associated with adhesive (Adper Single Bond 2). Twenty-four hemi-hourglass-shaped samples were repaired with each composite (n=12). Samples were divided according to groups...

Journal: :Photomedicine and laser surgery 2009
Atsushi Kameyama Koya Aizawa Junji Kato Yoshito Hirai

OBJECTIVE The purpose of this study was to evaluate the influence of Er:YAG laser irradiation on the bond strength to dentine of three single-step adhesives (AQ Bond Plus, G-Bond, and Clearfil Tri-S Bond), and one two-step self-etch adhesive (Clearfil Megabond) as a control. BACKGROUND DATA The vast majority of the numerous reports on resin bonding to Er:YAG-lased dentine have concluded that ...

Journal: :The journal of adhesive dentistry 2008
Koya Aizawa Atsushi Kameyama Junji Kato Yutaka Oda Yoshito Hirai

PURPOSE To compare effects of free-hand and mechanically applied uniform irradiation on tensile bond strength of 4-META/MMA-TBB resin to Er:YAG laser-irradiated dentin using an X-Y moving stage. MATERIALS AND METHODS Three different laser conditions were evaluated: 1.0 W, 100 mJ/pulse, 10 pps; 1.0 W, 50 mJ/pulse, 20 pps; 1.0 W, 33 mJ/pulse, 30 pps. Samples of bovine dentin were set on a movin...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه سیستان و بلوچستان 1390

abstract the influence of cation?? and anion?? interactions on the strength and nature of n…h hydrogen bond has been investigated by quantum chemical calculations in s-triazine…3hf complex. ab initio calculations were performed at mp2/6-311++g(d,p) level of theory. the natural bond orbital (nbo) analysis and the bader’s quantum theory of atoms in molecules (aim) were also used to elucidate t...

2017
V. S. Bagnato

The objective this study was to evaluate in vitro the bond strength of two etch-and-rise and one self-etching adhesive system after dentin irradiation with Er:YAG (erbium: yttrium aluminum garnet) laser using microtensile test. The results revealed that the groups treated with laser Er:YAG presented less tensile bond strength, independently to the adhesive system used. The prompt L-pop adhesive...

2007
Warren Batchelor R. Paul Kibblewhite Jihong He

The Page equation is the most widely used equation to predict the tensile strength of paper. In this paper, the derivation of the Page equation is examined critically and a modified Page equation is proposed based on a newly developed method to calculate the relative bonded area from sheet density and fibre shape. The predictions of the original and modified Page equations were then tested agai...

Journal: :The open dentistry journal 2015
A A R Khaledi M Bahrani S Shirzadi

STATEMENT OF THE PROBLEM Bonding failure between acrylic resin and soft liner material and also gradual loss of soft liner resiliency over time are two impending challenges frequently recognized with a denture base embraced with a resilient liner. Since patients drink various beverages, it is crucial to assess the influences of these beverages on physical characteristics of soft liners. PURPO...

Journal: :Operative dentistry 1999
M O Del Nero J C de la Macorra

The objectives of this research were (1) to analyze the variations of the permeability of dentin after restoration with two polyacid-modified resin composites (Compoglass, Dyract) and four single-bottle adhesives (Prime & Bond 2.0, Syntac Single Component, OptiBond Solo, and Single Bond--Scotch Bond 1 in Europe--immediately (approximately 1 hour) after insertion. A perfusion system with distill...

Journal: :Journal of applied oral science : revista FOB 2003
Marcelo Giannini Patrícia Chaves Marcelo Tavares de Oliveira

This in vitro study evaluated the effect of tooth age on the tensile bond strength of Prime & Bond NT adhesive system to dentin. Human third molars from the five age groups were analyzed: A- 17 to 20yrs, B- 21 to 30yrs, C- 31 to 40yrs, D- 41 to 50yrs and E- 51 to 63yrs. The occlusal enamel was removed using a diamond saw under water cooling and the dentin surface was wet-ground with 600-grit Si...

Journal: :Journal of international oral health : JIOH 2013
Deepa Shori Swapnil Pandey Rajesh Kubde Yogesh Rathod Rahul Atara Shravan Rathi

BACKGROUND Fiber posts are widely used for restoration of mutilated teeth that lack adequate coronal tooth structure to retain a core for definitive restoration, bond between the fiber post and composite material depends upon the chemical reaction between the post surface and the resin material used for building up the core. In attempt to maximize the resin bonding with fiber post, different po...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید