نتایج جستجو برای: surface dose

تعداد نتایج: 932650  

Background: Hysterosalpingography (HSG) is an indispensable tool for diagnosing infertility in females. The procedure exposes female reproductive organs to ionizing radiation as the genitals are irradiated during the process. Investigating patient absorbed dose during the procedures is essential for effective radiological protection of the patient. Objective: This study aims to investigat...

Background: Megavoltage beams used in radiotherapy are contaminated with secondary electrons. Different parts of linac head and air above patient act as a source of this contamination. This contamination can increase damage to skin and subcutaneous tissue during radiotherapy. Monte Carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in opt...

Journal: :The journal of physical chemistry. A 2007
Purnendu Chakraborty Michael R Zachariah

Atmospheric aerosols play a very important role in atmospheric processes and have a major influence on the global climate. In this paper, we report results of a molecular dynamics study on the unique properties of organic-coated water droplets. In particular, we find that, for particles preferring an inverted micelle structure, the lower chain-chain interaction, with increasing radial distance ...

C. Moon, C.M. Kang, H. Jang, H.J. Lee, J.C. Kim, J.H. Lee, S.H. Kim, S.K. Jo, U. Jung, Y. Yang,

Background: The trabecular bone changes in the tibia of C3H/HeN mice were measured 12 weeks after whole body irradiation with various doses of fast neutrons (0-2.4 Gy) or 137Cs-generated gamma-rays (0-6 Gy). Materials and Methods: Serum calcium, phosphorus, estradiol concentration and alkaline phosphatase activity were measured. Tibiae were anal...

Introduction: Coronary angiography is the most common angiographic procedure for diagnosis and treatment of the heart diseases. Herein, we aimed to evaluate the entrance surface dose (ESD), dose area product (DAP), as well as cancer risk in interventional cardiology procedures. Materials and Methods: This study was conducted during July-December 2015 at Shahid Madani Heart Center in Khorramabad...

2016
Christopher L. Guy Kishor Karki Manju Sharma Siyong Kim

As flattening filter-free (FFF) photon beams become readily available for treat-ment delivery in techniques such as SBRT, thorough investigation of skin dose from FFF photon beams is necessary under clinically relevant conditions. Using a parallel-plate PTW Markus chamber placed in a custom water-equivalent phantom, surface-dose measurements were taken at 2 × 2, 3 × 3, 4 × 4, 6 × 6, 8 × 8, 10 ×...

2013
Lukkana Apipunyasopon Somyot Srisatit Nakorn Phaisangittisakul

The percentage depth dose in the build-up region and the surface dose for the 6-MV photon beam from a Varian Clinac 23EX medical linear accelerator was investigated for square field sizes of 5 × 5, 10 × 10, 15 × 15 and 20 × 20 cm(2)using the EGS4nrc Monte Carlo (MC) simulation package. The depth dose was found to change rapidly in the build-up region, and the percentage surface dose increased p...

Journal: :iranian journal of medical physics 0
mohamad javad tahmasebi-birgani department of medical physics, jundishapuruniversity of medical sciences, ahvaz, iran mohamad reza bayatiani radiotherapy and medical physics department of arak university of medical sciences&khansari hospital, arak, iran fatemeh seif radiotherapy and medical physics department of arak university of medical sciences&khansari hospital, arak, iran mansur zabihzadeh department of medical physics, jundishapuruniversity of medical sciences, ahvaz, iran hojatolah shahbazian department of medical physics, jundishapuruniversity of medical sciences, ahvaz, iran

introduction magnetic fields are capable of altering the trajectory of electron beams andcan be used in radiation therapy.theaim of this study was to produce regions with dose enhancement and reduction in the medium. materials and methods the ndfeb permanent magnets were arranged on the electron applicator in several configurations. then, after the passage of the electron beams (9 and 15 mev va...

J. Fleckenstein, M.C. Miao, R.H. Zhang, W.W. Bai, Y.L. Gao, Z.F. Chi,

Background: As the volumetric modulated arc therapy (VMAT) becoming a main role of treatment ways, the effect of couch top becomes more significant. It is imperative to re-evaluate the couches that previously may have been considered of no importance during early treatment techniques. The impact of couch top on radiation delivery was explored and the couch model was tested with the aim of reduc...

Journal: :iranian journal of pharmaceutical research 0
s hesami takallu m rezaei tavirani sh kalantari m amir bakhtiarvand sm mahdavi

human serum albumin (hsa) is the most abundant plasma protein in the human body. hsa plays an important role in drug transport and metabolism. this protein has a high affinity to a very wide range of materials, including metals such as cu2+ and zn2+, fatty acids, amino acids and metabolites such as bilirubin and many drug compounds. in this study, we investigated the effects of co-amoxiclav, as...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید