نتایج جستجو برای: standard automated perimetry

تعداد نتایج: 636646  

Journal: :Investigative ophthalmology & visual science 2004
Nicolaas J Reus Hans G Lemij

PURPOSE To investigate the relationship between retinal light sensitivity measured with standard automated perimetry (SAP) and retardation of the peripapillary retinal nerve fiber layer (RNFL) measured with the GDx VCC (Laser Diagnostic Technologies, Inc., San Diego, CA). METHODS Forty-seven healthy subjects and 101 patients with glaucoma were examined with SAP and with the commercially avail...

Journal: :Investigative ophthalmology & visual science 2001
P G Spry C A Johnson A M McKendrick A Turpin

PURPOSE To evaluate and compare intra- and intertest variability components for both standard automated perimetry (SAP) and frequency-doubling technology (FDT) perimetry in a small group of normal individuals and patients with glaucoma. METHODS The method of constant stimuli (MOCS) was used to examine matched test locations with both SAP and FDT perimetry stimuli in a group of eight normal in...

Journal: :journal of current ophthalmology 0
حیدر امینی heidar amini علیرضا خدابنده alireza khodabande ساسان مقیمی sasan moghimi یداله اسلامی yadollah eslami رضا زارعی reza zarei قاسم فخرایی ghasem fakhraie

purpose: to quantify the intraobserver reproducibility of retinal nerve fiber layer (rnfl) measurements using scanning laser polarimetry with variable corneal compensation in glaucoma suspect patients. methods: twenty-six eyes of 26 glaucoma suspect patients were included. complete ophthalmologic examination and standard automated perimetry were performed for all of them. rnfl measurements were...

2012
Linda Zangwill

Technologies to Detect Glaucomatous Visual Field Damage There are several ways to identify glaucomatous defects from standard automated perimetry (SAP) print outs (Figure 1). Firstly, inspect sensitivity thresholds at each test point. It is not particularly useful to identify defects, because these values are not age-corrected. In older patients low thresholds could be attribdepression that cou...

Journal: :Optometry and vision science : official publication of the American Academy of Optometry 2003
Richard J Jamara Frans Van De Velde Eli Peli

Sparing or partial recovery of visual fields in hemianopic patients is frequently difficult to document. This is because when testing large field losses, the standard automated or manual visual field testing systems have limited fixation controls. Measured visual field recovery in these cases may not be real but instead may be due to an artifact such as scanning eye movement. This article illus...

Journal: :JAPANESE ORTHOPTIC JOURNAL 1986

Journal: :The British journal of ophthalmology 1997
M C Westcott A I McNaught D P Crabb F W Fitzke R A Hitchings

BACKGROUND Automated perimetry is of fundamental importance in assessing visual function in glaucoma. A technique was evaluated to perform high spatial resolution automated perimetry to allow a more detailed assessment of the luminance sensitivity in selected regions of the visual field than is possible with conventional perimetry. METHOD High spatial resolution perimetry was performed using ...

Journal: :Neurology India 2002
S Sood N K Sharma M Nada A Dutt R C Nagpal

An attempt was made to correlate various types of visual field defects on automated perimetry with the findings of computed tomography in 44 patients of supratentorial tumors. All the patients above the age of 10 years were subjected to complete neurological examination including investigations like plain X-rays and CT scan, however, MRI and angiography were performed wherever indicated. Ocular...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید