نتایج جستجو برای: sp34 slab phantom

تعداد نتایج: 27243  

2009
G. Li C. Sauerbier D. Paul W. Zhang Q. He M. Beckmann L. Lauer

Introduction Use of nonselective refocusing pulses shortens the echo spacing and the echo train duration, and then improves the image sharpness in SPACE [3, 4] imaging. However, the nonselective refocusing pulses limit the application of slab selective acquisition. To overcome this limitation, a dual echo-spacing technique [1] has been presented before, using a combination of selective excitati...

Journal: :iranian journal of radiation research 0
a. mesbahi medical physics department, medical school and radiation oncology department, imam khomeini hospital, tabriz university of medical sciences, tabriz, iran

background: prediction of the absorbed dose in irradiated volume plays an important role in the outcome of radiotherapy. application of small fields for radiotherapy of thorax makes the dose calculation process inaccurate due to the existence of electronic disequilibrium and intrinsic deficiencies in dose calculation algorithms. to study the lung absorbed dose in radiotherapy with small fields,...

Journal: :iranian journal of radiation research 0
s. senthilkumar department of radiotherapy, govt. rajaji hospital and madurai medical college, maduari-625 020, india v. ramakrishnan deptartment of laser studies, madurai kamaraj university, madurai, tamil nadu, india

background: the heterogeneous composition of the human body presents numerous tissue types and cavities with widely differing radiologic properties. the aim of the present work was to develop a low cost homogeneous and heterogeneous phantom and the absorbed dose were measured by ionization chamber for different radiotherapy treatment techniques and compared with treatment planning system absorb...

Journal: :علوم پیراپزشکی و بهداشت نظامی 0
سید سلمان ذکریایی seyed salman zakariaee department of radiology, faculty of paramedicine, aja university of medical sciences, tehran, iranگروه رادیولوژی، دانشکده ی پیراپزشکی، دانشگاه علوم پزشکی ارتش، تهران، ایران. ولی اله صبا valiallah saba department of radiology, faculty of paramedicine, aja university of medical sciences, tehran, iranگروه رادیولوژی، دانشکده ی پیراپزشکی، دانشگاه علوم پزشکی ارتش، تهران، ایران.

introduction: in diagnostic and therapeutic procedures, dosimetric studies are performed on the dosimetric systems in order to comply the radiation safety standards. monte carlo methods are used due to the high complexity and cost of patient-specific phantom construction. the high complexity of the digitized phantoms greatly increases the time and computational task of the monte carlo calculati...

In present study, a mathematical model of the vehicle–floating slab track (FST) interaction is established to investigate the coupled behaviour of vehicle–track system. The FST is modelled as the double Euler -Bernoulli beam including the rail and slab. The railway vehicle is simplified as a multi-rigid-body model. The wheel–rail interface is treated using a nonlinear Hertzian contact model, co...

Background: Prediction of the absorbed dose in irradiated volume plays an important role in the outcome of radiotherapy. Application of small fields for radiotherapy of thorax makes the dose calculation process inaccurate due to the existence of electronic disequilibrium and intrinsic deficiencies in dose calculation algorithms. To study the lung absorbed dose in radiotherapy with smal...

Journal: :Magnetic resonance imaging 2006
David Alberg Holm Karam Sidaros

OBJECTIVE An important source of error in arterial spin labeling (ASL) is incomplete static tissue subtraction due to imperfect slice profiles. This effect can be reduced by saturating the spins in the imaging area prior to labeling. In this study, the use of optimized presaturation is compared with the use of optimized RF pulses for minimizing this error. MATERIALS AND METHODS Different meth...

2011
Indra J. Das Minsong Cao Chee‐Wai Cheng Vladimir Misic Klaus Scheuring Edmund Schüle Peter A.S. Johnstone

Electronic portal imaging device (EPID) plays an important role in radiation therapy portal imaging, geometric and dosimetric verification. Consistent image quality and stable radiation response is necessary for proper utilization that requires routine quality assurance (QA). A commercial 'EPID QC' phantom weighing 3.8 kg with a dimension of 25 × 25 × 4.8 cm³ is used for EPID QA. This device ha...

Journal: :Magnetic resonance in medicine 2004
C Stehning P Börnert K Nehrke H Eggers O Dössel

A shortcoming of current coronary MRA methods with thin-slab 3D acquisitions is the time-consuming examination necessitated by extensive scout scanning and precise slice planning. To improve ease of use and cover larger parts of the anatomy, it appears desirable to image the entire heart with high spatial resolution instead. For this purpose, an isotropic 3D-radial acquisition was employed in t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید