Peter L. Roberson Jean M. Moran Ravi Kulasekere

Radiographic film dosimetry provides fast, convenient 2-D dose distributions, but is challenged by the dependence of film response on scatter conditions (i.e., energy dependence). Verification of delivered dose in the surface buildup region is important for intensity modulated radiation therapy (IMRT) when volumes of interest encroach on these regions (e.g., head/neck, breast). The current work...

Journal: :Physics in medicine and biology 2013
P H Charles S B Crowe T Kairn R T Knight B Hill J Kenny C M Langton J V Trapp

Due to their small collecting volume, diodes are commonly used in small field dosimetry. However, the relative sensitivity of a diode increases with decreasing small field size. Conversely, small air gaps have been shown to cause a significant decrease in the sensitivity of a detector as the field size is decreased. Therefore, this study uses Monte Carlo simulations to look at introducing air u...

2017
Kananan Utitsarn Nauljun Stansook Michael L. F Lerch Marco Petasecca Anatoly B. Rosenfeld

We evaluate the impact of an air gap and optimization of this air gap for the MP512 silicon detector array when operated in dosimetry mode for small photon field measurements in solid water. We present output factor measurements for 6MV and 10 MV photon beams with the square field sizes ranging from 0.5 to 10 cm2. The size of the air gap above the MP512 detector was changed from 0.5, 1.0, 1.2, ...

Journal: :Australasian Physical & Engineering Sciences in Medicine 2017

Journal: :Physics in medicine and biology 2015
N Ploquin G Kertzscher E Vandervoort J E Cygler C E Andersen P Francescon

A dosimetry system based on Al2O3:C radioluminescence (RL), and RADPOS, a novel 4D dosimetry system using microMOSFETs, were used to measure total scatter factors, (S(c,p))(f(clin))(det), for the CyberKnife robotic radiosugery system. New Monte Carlo calculated correction factors are presented and applied for the RL detector response for the 5, 7.5 and 10 mm collimators in order to correct for ...

Journal: :Applied sciences 2023

Background: Small-field dosimetry remains an open challenge globally. Thus, it is crucial to consider adequate reference codes of practice for the performance dosimetry. Furthermore, as part good clinical practice, implementation new implies development a audit program. In this work, pilot dosimetric protocol established measuring absolute dose in water small fields using micro-TLDs LiF:Mg,Ti d...