نتایج جستجو برای: shell tube heat exchanger
تعداد نتایج: 351012 فیلتر نتایج به سال:
An experimental study of heat transfer characteristics with and without insert was found using water –water system on 1-2 pass shell and tube heat exchanger. Experimental results such as exchanger effectiveness, overall heat transfer coefficient were calculated using with and without insert. There is improvement in overall heat coefficient, efficiency in using twisted tape. In all the process i...
In this numerical study, the heat transfer performance of shell-and-tube exchangers (STHXs) has been compared for two different tube arrangements. STHX having 21 and 24 tubes arranged in inline staggered grid considered analysis. Shell-and-tube exchanger with arrangement observed to provide lesser thermal stratification as arrangement. Further, study variation mass flow rate shell-side fluid co...
in this paper, overall heat transfer coefficient and friction factor of water based γ-al2o3 nanofluid in a double tube counter flow heat exchanger have been measured experimentally under turbulent flow condition. for better dispersion of γ-al2o3 nanoparticles in distilled water, magnetic stirrer and ultrasonic vibrator (with a power of 240 kw and frequency of 35 khz) were implemented. the stabi...
This paper presents experimental investigation carried out on an unmodified four stroke diesel engine running with preheated straight vegetable oil (SVO) of Karanja. The viscosity of straight karanja oil was reduced by preheating the oil up to 1600C under different load condition. The preheating was done with the help of a Shell and Tube heat exchanger equipment without using any external power...
Ionanofluids are a new and innovative class of heat transfer fluids which exhibit fascinating thermophysical properties compared to their base ionic liquids. This paper deals with the findings of thermal conductivity and specific heat capacity of ionanofluids as a function of a temperature and concentration of nanotubes. Simulation results using ionanofluids as coolants in heat exchanger are al...
Heat EXchangers (HEX) that are used in City Gate Station (CGS) systems are modeled numerically to recover the exhaust waste heat. It was tried to find the best viscous model to obtain results in accordance with experimental results and to change the heat exchanger design. This HEX is used for recovering heat from exhaust flue gas with a mixture of 40% water and 60% ethylene glycol as the coolin...
In present work, comparison of three different tube bundles for particular heat exchanger is proposed. Three types are smooth, micro finned and corrugated tubes. Heat exchanger will be designed with smooth tube bundle and simulated. Micro fin and corrugation over tube is applied separately for same heat exchanger in feasible size and simulated for performance. Besides, comparison is done with h...
This report contains the results of attempting to improve on the results of Scott R. Sawyer and Alan M. L’Esperance research paper “Investigation of Paraffin Wax as an Energy Storage Medium Within a Shell-and-Tube Heat Exchanger.” The overall goal of the paper mentioned was to investigate the usefulness of wax as an energy storage medium. Scott R. Sawyer and Alan M. L’Esperance determined that ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید