نتایج جستجو برای: self saf monte carlo simulation

تعداد نتایج: 1105029  

Journal: :iranian journal of nuclear medicine 0
mohsen hajizadeh saffar medical physics research center, school of medicine, mashhad university of medical sciences, mashhad, iran shabnam oloomi medical physics department, mashhad university of medical science, mashhad, iran peter knoll department of nuclear medicine, wilhelminenspital, vienna, austria hadi taleshi department of medical physics, faculty of medical sciences, tarbiat modares university, tehran, iran

introduction: scattered photon is one of the main defects that degrade the quality and quantitative accuracy of nuclear medicine images. accurate estimation of scatter in projection data of spect is computationally extremely demanding for activity distribution in uniform and non-uniform dense media. methods: the objective of this paper is to develop and validate a scatter correction technique t...

Journal: :The Annals of Applied Statistics 2011

Journal: :Medical physics 2015
Ioannis Sechopoulos Elsayed S M Ali Andreu Badal Aldo Badano John M Boone Iacovos S Kyprianou Ernesto Mainegra-Hing Kyle L McMillan Michael F McNitt-Gray D W O Rogers Ehsan Samei Adam C Turner

The use of Monte Carlo simulations in diagnostic medical imaging research is widespread due to its flexibility and ability to estimate quantities that are challenging to measure empirically. However, any new Monte Carlo simulation code needs to be validated before it can be used reliably. The type and degree of validation required depends on the goals of the research project, but, typically, su...

B. Dizangian , M. R Ghasemi,

A Reliability-Based Design Optimization (RBDO) framework is presented that accounts for stochastic variations in structural parameters and operating conditions. The reliability index calculation is itself an iterative process, potentially employing an optimization technique to find the shortest distance from the origin to the limit-state boundary in a standard normal space. Monte Carlo simulati...

2014
H. Kosina S. Selberherr

Algorithms are presented which advance the state of the art in Monte Carlo device simulation in two ways. Firstly, a method of free-flight time calculation using a new self-scattering algorithm is described. A piecewise linear total scattering rate allows for an efficient reduction of self-scattering events. Secondly, a unique Monte Carlo-Poisson coupling scheme is adopted, which converges fast...

Journal: :journal of physical & theoretical chemistry 2008
z. varmaghani f. mollaamin l. pishkar b. khalili hadda

medicinal chemistry depends on many other disciplines ranging from organic chemistry andpharmacology to computational chemistry. typically medicinal chemists use the moststraightforward ways to prepare compounds. the validation of any design project comes from thebiological testing.studies of the binding site of vinblastine by a single cross—linking experiment identified it asbeing between resi...

Journal: :مهندسی قدرت ایران 0
ali saberi noughabi university of birjand, iran nader hatefi torshizi university of birjand, iran hamidreza najafi university of birjand, iran

in this paper, an interval approach is presented to achieve perfect selectivity and maximum sensitivity in distance relay zones, considering uncertainties. for this purpose, first, the uncertainties affecting the settings of the three zones of a distance relay are discussed. then, by using the monte-carlo simulation, the uncertainties are modelled and the impedances seen by the distance relay a...

Journal: :iranian journal of radiation research 0
s.h. mousavie anijdan department of medical physics and engineering, school of medicine, tehran university of medical sciences, tehran, iran a. shirazi department of medical physics and engineering, school of medicine, tehran university of medical sciences, tehran, iran s.r. mahdavi department of medical physics and engineering, school of medicine, tehran university of medical sciences, tehran, iran a. ezzati department of energy engineering, sharif university of technology, tehran, iran b. mofid department of radiation oncology, shahid beheshti university of medical sciences, tehran, iran s. khoei department of medical physics and engineering, school of medicine, tehran university of medical sciences, tehran, iran

background: gold nanoparticles (gnps) have been shown as a good radiosensitizer. in combination with radiotherapy, several studies with orthovoltage x-rays have shown considerable dose enhancement effects. this paper reports the dose enhancement factor (def) due to gnps in 18 megavoltage (mv) beams. materials and methods: different geometrical 50-nm gnps configurations at a concentration of 5 m...

Journal: :iranian journal of radiation research 0
e.m.t. harki salahaddin university, college of science, kurdistan of iraq, erbeel, iraq a.t. al-kinani al-mustenserya university, college of medicine, baghdad, iraq and supreme council for environment and natural reserves, doha, qatar

background: exposure conditions in ct examinations are quite different from conventional xray. in ct examination higher dose is given to patient in comparison with the dose in other diagnostic examinations. in order to calculate organ effective dose in chest ct, monte carlo simulation has been used in this study. materials and methods: the impact survey data were used to determine the parameter...

Journal: :journal of medical signals and sensors 0
daryoush shahbazi-gahrouei saba ayat

introduction: radioiodine therapy is an effective method for treating thyroid cancer carcinoma, but it has some affects on normal tissues, hence dosimetry of vital organs are important to weigh the risks and benefits of this method. the aim of this study is to measure the absorbed doses of important organs by mcnp (monte carlo n particle) simulation and comparing the results of different method...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید