نتایج جستجو برای: scatter data

تعداد نتایج: 2418087  

Journal: :Optics express 2012
Lu Bai Zhensen Wu Xiren Zou Yunhua Cao

A new semi-empirical seven-parameter BRDF model is developed in the UV band using experimentally measured data. The model is based on the five-parameter model of Wu and the fourteen-parameter model of Renhorn and Boreman. Surface scatter, bulk scatter and retro-reflection scatter are considered. An optimizing modeling method, the artificial immune network genetic algorithm, is used to fit the B...

2014
Marina Gashinova Kalin Kabakchiev Liam Daniel Edward Hoare Vladimir Sizov Mikhail Cherniakov

To develop forward-scatter radar (FSR) systems for use in maritime applications, a fundamental understanding of the operating environment is required. Currently, there is a lack of published experimental FSR sea clutter data at very low (near-zero) grazing angle over the sea. This data is necessary for the development of FSR systems for maritime applications. Therefore to facilitate further inv...

Ahmad Mostaar, Ghazaleh Sadrieh Khajoo Mahdi Salehi Barough Mohammad Ali Ostadrahimi

Introduction: In the last few decades, a lot of monte carlo codes have been introduced for medical applications. this is important because through simulation, we are fully independent of the spectral scattering factor that we are not able measure in real terms. The effect of the radiation energy, the dimension of the radiation field, the sensitive volume of the ion chamber on t...

2012
Matthias Baer Michael Hammer Michael Knaup Ingomar Schmidt Ralf Christoph Marc Kachelrieß

The purpose of this study was to evaluate different approaches for scatter artifact reduction in the field of dimensional computed tomography (CT). The methods we investigated can be subdivided into one software-based method and three hardware-based methods. The software-based method uses a Monte Carlo scatter simulation to estimate scatter intensities for an initial model of the geometrical an...

Journal: :مدیریت صنعتی 0
علی مروتی شریف آبادی استادیار گروه مدیریت صنعتی، دانشکدۀ اقتصاد، مدیریت و حسابداری دانشگاه یزد، یزد، ایران مهناز باروت کوب کارشناس‎ارشد مدیریت صنعتی، دانشکدۀ اقتصاد، مدیریت و حسابداری دانشگاه یزد، یزد، ایران

one of methods of improvement of the material flow is cross docking that in is considered as a good method to reduce inventory and improve customer satisfaction. too, the vehicle routing problem is one of the important problems in distribution management and its goal is to find paths for delivering various cargos. therefore, this study was conducted in order to vehicle routing problem with cros...

Journal: :iranian journal of basic medical sciences 0
shabnam oloomi department of medical physics, mashhad university of medical science, mashhad, iran hadi noori eskandari department of applied mathematics, school of mathematical sciences, ferdowsi university of mashhad, mashhad, iran seyed rasoul zakavi nuclear medicine research center, imam reza hospital, faculty of medicine, mashhad university of medical sciences, mashhad, iran peter knoll department of nuclear medicine wilhelminenspital vienna, austria faraz kalantari research center for nuclear medicine, tehran university of medical sciences, tehran, iran mohsen hajizadeh saffar department of medical physics, mashhad university of medical science, mashhad, iran

objective(s): in spect, the sinogram contains scatter and lack of attenuated counts that degrade the reconstructed image quality and quantity. many techniques for attenuation and scatter correction have been proposed. an acceptable method of correction is to incorporate effects into an iterative statistical reconstruction. here, we propose new maximum likelihood expectation maximization (mlem) ...

2005
Jung-Kyun Bong Jong Doo Lee

Purpose: Abutted scatter energy windows used for a triple energy window (TEW) method may provide wrong estimation of scatter. This study is to propose an extended TEW (ETEW) method, which doesn't require abutted scatter energy windows and overcomes the shortcomings of TEW method. Materials & Methods: The ETEW is a modification of the TEW which corrects for scatter by using abutted scatter rejec...

2016
Sandeep Shetty Larsgunnar Nilsson

It is important to consider variations in material parameters in the design of automotive structures in order to obtain a robust and reliable design. However, expensive tests are required to gain complete knowledge of the material behavior and its associated variation. Consequently, due to time and cost constraints, simplifiedmaterial scatter modeling techniques based on scatter data of typical...

Jalil Pirayesh Islamian Mahdi Momennezhad Mohammad Taghi Bahreyni Toossi, Ramin Sadeghi Seyyed Rasool Zakavi

Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...

Journal: :Annals of nuclear medicine 2005
Jingming Bai Jun Hashimoto Koichi Ogawa Atsushi Kubo Atsushi Fukunaga Satoshi Onozuka Koichi Uchida

OBJECTIVE The aim of this study was to evaluate the effect of scatter and attenuation correction in region of interest (ROI) analysis in brain perfusion single-photon emission tomography (SPECT) and to assess the influence of selecting the reference area on semi-quantification. METHODS Ten normal subjects were enrolled and injected with 123I-iodoamphetamine to undergo simultaneous emission an...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید