نتایج جستجو برای: reinforced concrete shear wall

تعداد نتایج: 335966  

ژورنال: فناوری آموزش 2011
سعید بزازیان بناب محمود قضاوی,

: In the present paper, lessons are learnt from ant society so that humankind can optimize his engineering issues. As an example of such issues, a reinforced concrete retaining wall for which the application of optimization can reduce the costs involved is considered. Traditional design procedure for reinforced concrete retaining walls is unable to design an optimized wall unless a large trial ...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه تربیت مدرس 1386

چکیده ندارد.

2013
Brian J. Smith Yahya C. Kurama

This paper presents an analytical investigation on the peak lateral displacement demands of “hybrid” precast concrete panelized shear wall structures under seismic loading. The hybrid wall structure investigated uses a combination of mild [i.e., Grade 400 (U.S. Grade 60)] steel bars and highstrength unbonded post-tensioning (PT) strands for lateral resistance across horizontal joints. The analy...

2008
Jie Xiong Youjiang Wang

There is a growing need for the rehabilitation, repair, and upgrading of concrete structures such as bridges and buildings. The repair or rehabilitation of reinforced concrete structures often offers a lower cost alternative to rebuilding, and it is traditionally achieved by bonding steel plates to the tensile face of a reinforced concrete member. The shear strength can be enhanced with plates ...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه سمنان - دانشکده علوم پایه 1387

چکیده ندارد.

Journal: :international journal of civil engineering 0
m. mazloom civil engineering department

according to the iranian code of practice for seismic resistant design of buildings, soft storey phenomenon happens in a storey when the lateral stiffness of the storey is lower than 70% of the stiffness of the upper storey, or if it is lower than 80% of the average stiffness of the three upper stories. in the combined structural systems containing moment frames and shear walls, it is possible ...

Azadeh Alsadat Asghari Bahram Navayineya, Gholamreza Ghodrati Amiri, Morteza Hossein Ali Beigy Zahra Tabrizian,

. This paper presents the results of an experimental investigation on shear strength enhancement of reinforced concrete deep beams externally reinforced with fiber reinforced polymer (FRP) composites. A total of six deep beam specimens of two different classes, as-built (unstrengthened) and retrofitted were tested in the experimental evaluation program. Two composite systems namely carbon/epoxy...

2007
Trevor Kelly

A full scale slice of a 7 story reinforced concrete building was tested on the shake table at the UCSD Engelkirk Structural Research Centre in 2006. As part of the research project, a blind prediction contest was sponsored to assess the capability of currently available analysis procedures to predict the seismic response of cantilever reinforced concrete shear wall structures. This paper descri...

2007
M. Ofelia Moroni

Buildings with cast-in-situ reinforced concrete shear walls are widespread in many earthquake-prone countries and regions, such as Canada, Chile, Romania, Turkey, Colombia, the republics of the former Soviet Union, etc. This type of construction has been practiced since the 960s in urban regions for mediumto high-rise buildings (4 to 35 stories high). Shear wall buildings are usually regular in...

2012
P. Hannewald K. Beyer

Plastic hinge models are widely used in earthquake engineering to predict the load-deformation relationships of reinforced concrete members. For the seismic assessment of bridges, it is appealing to use those relatively simple models if the response is predicted with sufficient accuracy. The applicability of these models to wall-type bridge piers with weak seismic detailing is examined. Flexura...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید