BACKGROUND The long-term efficacy of radiofrequency ablation of renal autonomic nerves has been proven in nonrandomized studies. However, long-term safety of the renal artery (RA) is of concern. The aim of our study was to determine if cooling during radiofrequency ablation preserved the RA while allowing equivalent nerve damage. METHODS AND RESULTS A total of 9 swine (18 RAs) were included, ...
The novel carbidonitridosilicates Ho2[Si4N6C] and Tb2[Si4N6C] were obtained by the reaction of the respective lanthanoid metal with carbon and Si(NH)2 in a radiofrequency furnace at the temperature of 1700 uC. According to the single-crystal structure analysis of Ho2[Si4N6C] (P21/c, Z~4, a~593.14(1), b~989.74(1), c~1188.59(2) pm, b~119.58(4)u, R1~0.0355, wR2~0.0879, 2187 F values, 119 parameter...
IO N Materials that are both conductive and stretchable could enable a spectrum of applications such as stretchable displays, [ 1 ] stretchable radiofrequency antennas, [ 2 ] artifi cial muscles [ 3 ] and conformal skin sensors. [ 4–7 ] A variety of such materials have been recently developed, such as wavy thin metals, [ 8 , 9 ] metal-coated net-shaped plastic fi lm, [ 10 ] graphene fi lms [ 11...
A linearly chirped fiber Bragg grating (LCFBG) has been used as a temperature sensor for online monitoring of radiofrequency thermal ablation (RFTA). The LCFBG acts as a distributed sensor, with spatial resolution of 75 μm. A white-light setup that records the LCFBG spectrum estimates the temperature profile in real time. Three RFTA experiments have been performed ex-vivo on porcine liver measu...
STUDY DESIGN Retrospective chart review. OBJECTIVES To determine the success rate and duration of relief of repeat radiofrequency neurotomy for lumbar facet joint pain. SUMMARY OF BACKGROUND DATA Radiofrequency neurotomy is an effective but temporary management of lumbar facet pain. When pain recurs, radiofrequency neurotomy is usually repeated, but the outcome and duration of relief for re...
We describe a spectrometer for pulsed ENDOR at 140 GHz, which is based on microwave IMPATT diode amplifiers and a probe consisting of a TE011 cavity with a high-quality resonance circuit for variable radiofrequency irradiation. For pulsed EPR we obtain an absolute sensitivity of 3x10(9) spins/Gauss at 20 K. The performance of the spectrometer is demonstrated with pulsed ENDOR spectra of a stand...
Ablation of ventricular tachycardia (VT) by conventional radiofrequency ablation can be impossible if the ventricular wall at the targeted ablation site is very thick, as for example the ventricular septum. We present a case of a patient with incessant, non-sustained slow VT originating from the septal part of the lower outflow tracts. Radiofrequency catheter ablation from both ventricles as we...
OBJECTIVES We aimed to prospectively evaluate the response and safety of pulsed and continuous radiofrequecy lesioning of the dorsal root ganglion/segmental nerves in patients with chronic lumbosacral radicular pain. METHODS Seventy-six patients with chronic lumbosacral radicular pain refractory to conventional therapy met the inclusion criteria and were randomly assigned to one of 2 types of...
OBJECTIVES Surgical radiofrequency ablation is increasingly used during open heart surgery for the treatment of chronic atrial fibrillation. The purpose of this study was to determine the effects of application of radiofrequency on coronary endothelial function and structure and establish the relationship between coronary lesions and distance of radiofrequency application. METHODS Six Landrac...