نتایج جستجو برای: quartz crystal

تعداد نتایج: 168447  

Journal: :Colloids and surfaces. B, Biointerfaces 2014
P Losada-Pérez M Khorshid C Hermans T Robijns M Peeters K L Jiménez-Monroy L T N Truong P Wagner

In this work we examine the role of lateral phase separation in cholesterol-containing biomimetic membranes on the disrupting action of melittin using a label-free surface-sensitive technique, quartz crystal microbalance with dissipation monitoring (QCM-D). Melittin disruption mechanisms depend strongly on the geometry of the lipid layer; however, despite the interplay between layer geometry/th...

2011
Hans-Rudolf Wenk Christoph Janssen Thomas Kenkmann Georg Dresen

a r t i c l e i n f o Increasing use of diffraction methods to study preferred orientation of minerals has established that quartz in deformed rocks not only displays characteristic c-axis orientation patterns, but that there is also generally a distinct difference in the orientation of positive and negative rhombs. In the trigonal quartz crystal structure positive and negative rhombs are struc...

2016
Takuro Kobayashi Hidetoshi Kuramochi Kouji Maeda Kaiqin Xu

In anaerobic digestion (AD), long-chain fatty acids (LCFAs) produced by hydrolysis of lipids, exhibit toxicity against microorganisms when their concentration exceeds several millimolar. An absorption detection system using a quartz crystal microbalance (QCM) was developed to monitor the LCFA concentration during an anaerobic digester’s operation treating oily organic waste. The dissociation of...

Journal: :Biosensors & bioelectronics 2010
Gulsu Sener Erdogan Ozgur Erkut Yılmaz Lokman Uzun Ridvan Say Adil Denizli

The aim of this study is to prepare quartz crystal microbalance (QCM) nanosensor for the real-time detection of lysozyme. In the first part, the lysozyme imprinted (MIP) nanoparticles were prepared by mini-emulsion polymerization. The MIP nanoparticles were characterized by TEM, zeta-sizer and FTIR-ATR measurements. Particle size was found around 50 nm. The MIP nanoparticles were attached by dr...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2012
Shinichi Imai Hitoshi Watarai

The magnetic-force quartz crystal microbalance (QCM) method was attempted for the dynamic evaluation of chemical interactions. Thiol-modified magnetic particles bound to a QCM gold electrode of less than three layers were pulled by a magnetic force, and the dissociation dynamics of the magnetic particles was measured based on the change in the weight as a function of time under different tempe...

Journal: :The journal of physical chemistry. B 2009
Gang Hu John A Heitmann Orlando J Rojas

Quartz crystal microgravimetry (QCM) was used to investigate the interactions between cellulase enzymes and model cellulose substrates. The substrates consisted of thin films of cellulose that were spin-coated onto polyvinylamine (PVAm) precoated quartz crystal sensors carrying conductive gold surfaces. In QCM the quartz crystals are piezoelectrically driven and the frequency and dissipation sh...

2008
Dorothee Grieshaber Victoria de Lange Thomas Hirt Zhihua Lu Janos Vörös

The sensitivity of biosensors is often not sufficient to detect diagnostically relevant biomarker concentrations. In this paper we have utilized a Quartz Crystal Microbalance with Dissipation monitoring (QCM-D) to detect dissipative losses induced by the attachment of intact vesicles. We modified a sandwich assay by coupling the secondary antibodies to vesicles. This resulted in an increase of ...

2017
Xianhe Huang Qingsong Bai Qi Zhou Jianguo Hu

Due to the influence of liquid load, the equivalent resistance of in-liquid quartz crystal microbalance (QCM) increases sharply, and the quality factor and resonant frequency decreases. We found that the change in the resonant frequency of in-liquid QCM consisted of two parts: besides the frequency changes due to the mass and viscous load (which could be equivalent to motional inductance), the ...

2014
Yusuke Fuchiwaki Masato Tanaka Yoji Makita Toshihiko Ooie

The present work demonstrates a valuable approach to developing quartz crystal microbalance (QCM) sensor units inexpensively for reliable determination of analytes. This QCM sensor unit is constructed by inkjet printing equipment utilizing background noise removal techniques. Inkjet printing equipment was chosen as an alternative to an injection pump in conventional flow-mode systems to facilit...

2016
A. M. Baergen

Manuscript by Alyson Baergen and D. J. Donaldson focuses on formation of HONO, a key chemical species and/or reaction intermediate in atmospheric chemistry, during photolysis of urban grime. Given the fact that sources and formation of daytime HONO in urban setup are poorly understood, this study reveals potential chemical and photochemical reaction pathways and mechanisms to yield HONO. The kn...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید