نتایج جستجو برای: prosthesis

تعداد نتایج: 28327  

2018
Jigang Lou Beiyu Wang Tingkui Wu Wenjie Wu Huibo Li Ziyang Liu Hao Liu

BACKGROUND A study was designed to quantify the extent of porous osseointegration at the prosthesis-bone interface in the Prestige LP prosthesis containing a plasma-sprayed titanium coating. METHODS Using an anterior surgical approach, cervical disc arthroplasty was performed in 8 mature male goats at the C3-C4 segment, followed by implantation of the Prestige LP prosthesis. The vertebral spe...

2014
Monan Wang Qi Wang Kai Zhang

Based on the thermo elasticity, using finite element method to analyze the stress of femur-prosthesis system when the hip joint has been replaced, a reference for the selection of prosthesis material is presented after discussing the thermo physical property of material which has an effect on the stress of femur-prosthesis system. We assume that prosthesis, bone cement and femur are linear elas...

  Abstract   Background : Beam-hardening artifacts in CT image set of patient with a hip prosthesis cause difference between dose distributions resulted by treatment planning system (TPS) algorithms and actual dose distribution in patient body. In this study, dose distributions of TPS algorithms were compared with the results of Monte Carlo simulations of Titanium and Steal as a h...

2015
Nihat Karakoyunlu Sercan Sarı Harun Ozdemir Hikmet Topaloglu Ugur Ozok Levent Sagnak Hamit Ersoy

Penile prosthesis is a functional option for patients who have erectile dysfunction after failed medical and intracavernosal treatments. Malleable penile prosthesis is a good alternative. Penile prosthesis implantation is a surgical process. Seldomly complications occur. In this study we presented a 61 y old man who has malfunctioned and broken penile prosthesis due to cross implantation.

Journal: :Hearing research 2010
Jae Hoon Sim Michail Chatzimichalis Alexander M Huber

In the surgical treatment of otosclerosis, the coupling between the stapes prosthesis and the long process of the incus is critical. After surgery, connective tissue and mucosa may grow over the coupling area and thereby influence the sound transmission properties of the incus-prosthesis interface. It was the hypothesis of this study that tissue ongrowth in the incus-prosthesis interface has li...

Journal: :Head & neck 2008
Lynn M Acton Douglas A Ross Clarence T Sasaki Steven B Leder

BACKGROUND This study investigated the patient's self-report and clinician's confirmation of tracheoesophageal voice prosthesis leakage patterns (through or around) with or without the cough reflex and whether prosthesis diameter affected the leakage route. METHODS Sixty-six consecutive participants with a total of 200 patient-initiated reasons for prosthesis changes were enrolled prospective...

2011
Gokce Soganci Suat Yalug Mustafa Kocacikli

This report describes a different approach for diminishing the movements of orbital prosthesis during mimic movements and chewing function. Mechanical devices such as magnets are used to enhance the retention in case lack of the implants. However rigid fixation of obturator and orbital prosthesis can result in movements of the orbital prosthesis during mastication. In this case obturator and or...

Journal: :Technology and health care : official journal of the European Society for Engineering and Medicine 2011
Ulrich Wiebking Björn Birkenhauer Christian Krettek Thomas Gösling

BACKGROUND Use of the proximal part of the femur in total hip arthroplasty enables preservation of the distal femur for later revisions. To use this advantage, different types of short-stem prosthesis have been developed in recent years. Although cementless hip arthroplasty is not common in the treatment of canine osteoarthritis, the use of cementless short-stems might be an alternative therapy...

2017
Jigang Lou Yuanchao Li Beiyu Wang Yang Meng Tingkui Wu Hao Liu

In vitro biomechanical analysis after cervical disc replacement (CDR) with a novel artificial disc prosthesis (mobile core) was conducted and compared with the intact model, simulated fusion, and CDR with a fixed-core prosthesis. The purpose of this experimental study was to analyze the biomechanical changes after CDR with a novel prosthesis and the differences between fixed- and mobile-core pr...

Journal: :The Laryngoscope 2011
Daniel G Deschler Kevin S Emerick Derrick T Lin Glenn W Bunting

OBJECTIVES Secondary tracheoesophageal (TE) puncture standardly involves placement of a catheter at time of TE fistula creation. We explore the feasibility of placement of the prosthesis at the time of TE puncture (TEP) obviating the need for a subsequent procedure to place the prosthesis. We describe the technique and evaluate the success and potential advantages. STUDY DESIGN Retrospective ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید