Ti/PbO2/Sb2O3 electrode was used as indicator electrode in potentiometric and conductometric titration in aqueous solution at 298 K. The E-pH curve is linear with a slope of 0.0505 V/dec at 298 K which is close to the theoretical value 2.303RT/F (0.059 V at 298 K). The standard potential of this electrode, E, is computed with respect to the SCE as reference electrode. The recovery percentages f...
The irradiation of a series of phenyl sulfonates and phosphates leads to the quantitative release of acidity with a reasonable quantum yield (≈0.2). Products characterization, ion chromatography analysis and potentiometric titration are consistent with the intervening of two different paths in this reaction, viz. cationic with phosphates and (mainly) radical with sulfonates.
Potentiometric and spectrophotometric titrations of staphylococcal enterotoxin B have been carried out in 0.16 M KC1 at 25”. Potentiometric titration results indicate that the titration curves are essentially reversible between pH 1.50 and 11.0. All of the ionizable groups in enterotoxin B found from the titration curves are consistent with the amino acid composition which has been reported in ...
A plasticized Cr3+ ion sensor by incorporating 2,3,8,9-tetraphenyl-1,4,7,10-tetraazacyclododeca-1,3,7,9-tetraene (TTCT) ionophore exhibits a good potentiometric response for Cr3+ over a wide concentration range (1.0 x 10(-6)-1.0 x 10(-1) M) with a slope of 19.5 mV per decade. The sensor response is stable for at least three months. Good selectivity for Cr3+ in comparison with alkali, alkaline e...
Potentiometric sensor based on commercial pencil graphite electrodes coated with polyaniline (PAni) composite with Eosin Y (EY) termed as PGE/PAni-EY have been developed for potentiometric determination of silver ion. The electrode exhibited linear response with Nernstian slope of 57.6±0.8 mV per decade within the range of 1.0×10 to 1.0×10 M with limit of detection 6.5×10 M silver ion. Fast and...
This paper describes a microfluidic device, fabricated in poly(dimethylsiloxane), that is used for potentiometric titrations. This system generates step gradients of redox potentials in a series of microchannels. These potentials are probed by microelectrodes that are integrated into the chip; the measured potentials were used to produce a titration curve from which the end point of a reaction ...
An efficient one-pot microwave-assisted hydrogenation of codeine was achieved in aqueous solution. This technique is simple, fast, environmentally friendly, and highly efficient. Structure of produced dihydrocodeine was approved by using FT-IR, (1)H NMR, (13)C NMR, EIMS, and elemental analysis technique. Its purity analysis was performed by using HPLC and assay analysis was performed by using p...
Coulometric titrations of mineral acids, sulphonic acids, carboxylic acids, enols, imides and phenols have been carried out in t-butanol or in acetone with electrically generated tetrabutylammonium hydroxide. Either a potentiometric titration or a visual indicator end-point may be used. The amount of acid titrated ranges from 10 to 60 muequiv, and the precision and accuracy of the method are ex...
Zirconium oxy-salts were hydrolyzed to form positively charged polymer or cluster species in acidic solutions. The zirconium hydrolyzed polymer was found to react with a negatively charged polyelectrolyte, such as poly(vinyl sulfate), and to form a stoichiometric polyion complex. Thus, colloidal titration with poly(vinyl sulfate) was applied to measure the zirconium concentration in an acidic s...