نتایج جستجو برای: potentiometric sensor
تعداد نتایج: 191184 فیلتر نتایج به سال:
The fabrication and application of an intracellular K + -selective microelectrode is demonstrated. ZnO nanowires with a diameter of 100–180 nm and a length of approximately 1.5 μm are grown on a borosilicate glass microcapillary. The ZnO nanowires were coated by a K + -ionophore-containing membrane. The K + -selective microelectrode exhibited a K + -dependent potentiometric response versus an A...
tin(ii)-ion-selective electrode consisting of dibenzo-18-crown-6 (db18c6) as an ionophore inpvc matrix was developed. the influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. the electrodeshowed a near nernstian response for sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27...
A potentiometric electronic tongue was applied to study the release of valsartan from pharmaceutical formulations, i.e., minitablets uncoated and coated with Eudragit E. Special attention was paid to evaluate the influence of medium temperature and composition, as well as to compare the performances of the sensor arrays working in various hydrodynamic conditions. The drug dissolution profiles r...
چکیده ندارد.
Potentiometric sensor based on commercial pencil graphite electrodes coated with polyaniline (PAni) composite with Eosin Y (EY) termed as PGE/PAni-EY have been developed for potentiometric determination of silver ion. The electrode exhibited linear response with Nernstian slope of 57.6±0.8 mV per decade within the range of 1.0×10 to 1.0×10 M with limit of detection 6.5×10 M silver ion. Fast and...
Magnesium assays are being increasingly requested in hospitals and clinical research institutions. The ionized form of magnesium (iMg) is regarded as the biologically active fraction. Ionophore-based potentiometric sensors can determine iMg and apply a selectivity correction for co-existing interfering electrolytes, e.g. Ca 2+ . This technology has been used in several commercial blood analyzer...
This paper reports on the development of a micro-potentiometric sensor based on external microelectrodes introduced into a microchip. We miniaturized reference and ion-selective electrodes (ISEs) and embedded them into a plastic (PDMS) microchip; the miniaturization of ISE was attained by using a monolithic capillary-based membrane. This sensor was applied to the detection of alkali ions (Na+, ...
Membranes of 4-tert-butylcalix(8)arene-octaacetic acid octaethyl ester (I) as an electroactive material, sodium tetraphenyl borate (NaTPB) as an anion excluder, and tri-n-butyl phosphate (TBP) as a solvent mediator in poly(vinyl chloride) (PVC) matrix have been tried for a strontium-selective sensor. The best performance was exhibited by the membrane having a composition 5:100:150:2 (I: PVC: TB...
The introduction of low detection limit ion selective electrodes (ISEs) may well pave the way for the determination of trace targets of cationic compounds. This research focuses on the detection of titanium (III) cation using a new PVC-membrane sensor based on synthesized tris(2pyridyl) methylamine (tpm) ionophore. The application and validation of the proposed sensor was done using potentiomet...
Tin(II)-ion-selective electrode consisting of dibenzo-18-crown-6 (DB18C6) as an ionophore inPVC matrix was developed. The influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. The electrodeshowed a near Nernstian response for Sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید