نتایج جستجو برای: polymer gel dosimeter nipam
تعداد نتایج: 195981 فیلتر نتایج به سال:
Abstract Three different dosimetry systems were prepared based on diphenyl thiocarbazone (DTH) dye: polymer films made with, poly(vinyl alcohol), DTH liquid dosimeter and gel dosimeter. All the received several gamma doses. The three analyzing by UV–Vis spectrophotometery before after irradiation. effective dose range in linear part of these is between 1–10 kGy, 0.3–2 50–200 Gy. dosimeters reli...
Changes in the linear attenuation coefficient of polymer gel dosimeters post-irradiation enable the imaging of dose distributions by x-ray computed tomography (CT). Various compositions of polymer gel dosimeters manufactured from acrylamide (AA), and N,N'-methylene-bis-acrylamide (BIS) comonomers and gelatin or agarose gelling agents were investigated. This work shows that increasing the comono...
This study extends the 'zero scan' method for CT imaging of polymer gel dosimeters to include multislice acquisitions. Multislice CT images consisting of 24 slices of 1.2 mm thickness were acquired of an irradiated polymer gel dosimeter and processed with the zero scan technique. The results demonstrate that zero scan-based gel readout can be successfully applied to generate a three-dimensional...
Introduction: The PAGAT polymer gel dosimeter melts at 30 ˚C and even at room temperature during the summer, so it needs to be kept in a cool place such as a refrigerator. To increase the stability of the PAGAT gel, different amounts of agarose were added to the PAGAT gel composition and the PAGATA gel was manufactured. Material and Methods: The PAGATA gel vials were irradiated using a Co-60 ma...
Poly(N-isopropyl acrylamide) (pNIPAM) is one of the most popular stimulus-responsive polymers for research. It is especially of great interest in the field of tissue engineering. While it is known that the NIPAM monomer is toxic, there is little conclusive research on the cytotoxicity of the polymer. In this work, the relative biocompatibility of the NIPAM monomer, pNIPAM, and pNIPAM-coated sub...
A feasibility study of proton beam PET/CT off-line quantitative dosimetry using polymer gels is presented. A newly developed proton-sensitive polymer gel dosimeter (BANG®3-Pro2) is used as a dosimeter and a tissue-equivalent phantom medium for this study. We explore a new approach to correlating measured proton 3-dimensional (3D) dose distributions directly to measured positron emission from in...
background: radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like developed to date. among the special features of this type of dosimeters, is be doped with other elements or chemicals which made them appropriate for investigating of dose enhancement with contrast agents, by high atomic number. material and methods: in this study...