نتایج جستجو برای: photon dose distribution mcnp code percentage depth dose

تعداد نتایج: 1376868  

A. Afzali, A.A. Mowlavi, N. Afzali,

Background: Skin cancer can be treated by various methods. Electron radiotherapy has been a useful therapeutic modality in the treatment of skin cancers in areas which are difficult to cure by other methods. Depth dose distribution of 166Ho using VARSKIN2 code is presented in this work. Material and Methods: Depth dose distribution of 166Ho was calculated, using VARSKIN2 code by adding...

Journal: :iranian journal of medical physics 0
mohammad javad t ahmasebi associated professor, medical physics & radiotherapy dept., golestan hospital, ahwaz university of medical sciences, ahwaz, iran mohammad ali behrooz professor, medical physics dept., ahwaz university of medical sciences, ahwaz, iran shole arvandi assistant professor, radiotherapy & oncology dept., golestan hospital, ahwaz university of medical sciences, ahwaz, iran davood khezerloo m.sc. medical physics dept., ahwaz university of medical sciences, ahwaz, iran mojtaba karbalai m.sc. medical physics dept., golestan hospital, ahwaz university of medical sciences, ahwaz, iran

introduction: nowadays,  considerable developments  in  the field  of  radiotherapy have  been  achieved.  they  include  the  advances  made  in  the  equipments  and  treatment  planning  techniques  which  require  highly complex calculations. such achievements have made it possible to treat cancer patients not only  with  higher  radiation  dose  but  also  with  higher  precision  and  con...

Introduction: Physical wedge by modify photon beam shape and intensity has been utilized in radiotherapy to obtain uniformly dose distribution in tumor site with reduced hot spots. Calculation of dosimetric parameters for both symmetric and asymmetric wedged fields is proved necessary during linear accelerator (Linac) commissioning. The present study aimed to achieve o...

Journal: :journal of medical signals and sensors 0
hamid-reza sadoughi shahrokh nasseri mahdi momennezhad hamid-reza sadeghi mohammad hossein bahreyni

radiotherapy dose calculations can be evaluated by monte carlo (mc) simulations with acceptable accuracy for dose prediction in complicated treatment plans. in this work, standard, livermore and penelope electromagnetic (em) physics packages of geant4 application for tomographic emission (gate) 6.1 were compared versus monte carlo n-particle extended (mcnpx) 2.6 in simulation of 6 mv photon lin...

Background: Megavoltage beams used in radiotherapy are contaminated with secondary electrons. Different parts of linac head and air above patient act as a source of this contamination. This contamination can increase damage to skin and subcutaneous tissue during radiotherapy. Monte Carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in opt...

2015
Tran Van Hung

---------------------------------------------------------------------***--------------------------------------------------------------------Abstract The dose distribution in irradiation room and the dose rate at each dwell position of 60Co irradiator SVST-Co-60/B have been calculated using MCNP code. The calculated results are useful information to estimate radiation safety and design irradiato...

Journal: :iranian journal of radiation research 0
k.n. esnaashari department of medical physics tehran university of medical sciences, tehran, iran m. allahverdi department of medical physics tehran university of medical sciences, tehran, iran h. gharaati department of medical physics tehran university of medical sciences, tehran, iran m. shahriari department of medical radiation, shahid beheshti university, tehran, iran

background: stereotactic radiosurgery is an important clinical tool for the treatment of small lesions in the brain, including benign conditions, malignant and localized metastatic tumors. a dosimetry study was performed for elekta ‘synergy s ’ as a dedicated stereotactic radiosurgery unit, capable of generating circular radiation fields with diameters of 1-5 cm at isocentre using the beam/egs4...

2013
M. Shimizu Y. Morishita M. Kato T. Kurosawa T. Tanaka N. Takata

A graphite calorimeter has been developed as a Japanese primary standard of absorbed dose to water in the high-energy photon beams from a clinical linac. To obtain conversion factors for the graphite calorimeter, the beam characteristics of the highenergy photon beams from the clinical linac at National Metrology Institute of Japan were calculated with the EGS5 Monte Carlo simulation code. To r...

Journal: :iranian journal of radiation research 0
w. parwaie department of radiology, faculty of para-medicine, hormozgan university of medical sciences, bandar abbas, iran m. yarahmadi department of medical physics, faculty of medicine, kurdistan university of medical sciences, sanandaj, iran h.a. nedaie department of radiotherapy, cancer institute, tehran university of medical sciences, tehran, iran m.h. zahmatkesh shahid beheshti university of medical sciences, tehran, iran a.h. barati department of medical physics, faculty of medicine, kurdistan university of medical sciences, sanandaj, iran m. afkhami department of radiology, faculty of para-medicine, hormozgan university of medical sciences, bandar abbas, iran

background: accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (srs) and intensity modulated radiotherapy (imrt). precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. in the p...

آقامیری, محمودرضا , باغانی, حمیدرضا , حیدرلو, نعمت الله , مهدوی, ربیع ,

Background and purpose: Beam shaper is a type of applicator used in conjunction with the intraoperative electron radiotherapy. This study aimed at quantitative evaluation of the photon contamination of this applicator using Monte Carlo simulation. Materials and methods: In this experimental study, at first the head of LIAC accelerator was simulated along with the beam shaper applicator using...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید