A. Vyas P. Kumar R. Ravanfar Haghighi S. Chatterjee,

Introduction: The photoelectric attenuation coefficient of substances is known to depend upon the energy E of the photon and the effective atomic number of substances (Zeff) as (Zeffx/Ey).  No definitive values about these indices x, y are given in the literature. The index x is said to lie between, 3.0 and 4.0, while for ‘y’ different values have been assigned, between 3.0 and 4.0. Method...

Journal: :iranian journal of medical physics 0
mehdi zehtabian ray medical engineering department, school of mechanical engineering, shiraz university, shiraz iran elham piruzan ray medical engineering department, school of mechanical engineering, shiraz university, shiraz iran zahra molaiemanesh ray medical engineering department, school of mechanical engineering, shiraz university, shiraz iran

introduction lead-based shields are the most widely used attenuators in x-ray and gamma ray fields. the heavy weight, toxicity and corrosion of lead have led researchers towards the development of non-lead shields. materials and methods the purpose of this study was to design multi-layered shields for protection against x-rays and gamma rays in diagnostic radiology and nuclear medicine. in this...

Elham Piruzan Mehdi Zehtabian, Sedigheh Sina Zahra Molaiemanesh,

Introduction Lead-based shields are the most widely used attenuators in X-ray and gamma ray fields. The heavy weight, toxicity and corrosion of lead have led researchers towards the development of non-lead shields. Materials and Methods The purpose of this study was to design multi-layered shields for protection against X-rays and gamma rays in diagnostic radiology and nuclear medicine. In this...

Journal: :iranian journal of medical physics 0
ali shabestani monfared biochemistry and biophysics department, babol university of medical sciences, shahid rajaee oncology hospital, babolsar, iran

introduction superficial x-ray therapy is one of the most important treatment methods in radiotherapy especially in the treatment of superficial skin lesions (up to 300 kvp). quality of the x-ray beam that can be expressed by half-value layer (hvl), are important indices for this type of treatment effective energy of photon and homogeneity coefficient (hc). materials and methods the hc of the s...

ژورنال: سنجش و ایمنی پرتو 2016

By use of silicon rubber as polymeric matrix and bismuth oxide as fillers, composite materials were fabricated up to 70 wt% and their gamma ray attenuation was studied. Due to the fair solubility of bismuth oxide particles in polymer matrix, the solution intercalation method is used for nanocomposite fabrication. The applied source for radiation attenuation test was 241Am with photon energies 5...

2009
Marcelo O. Pereira Marcelino J. Anjos Ricardo T. Lopes

Non-destructive techniques with X-ray, such as tomography, radiography and X-ray fluorescence are sensitive to the attenuation coefficient and have a large field of applications in medical as well as industrial area [1,2]. In the case of X-ray fluorescence analysis the knowledge of photon X-ray attenuation coefficients provides important information to obtain the elemental concentration. On the...

Ali Shabestani Monfared, Ali-Reza Shirazi Hamed Babapour Tayyeb Allahverdi Pourfallah

Introduction Superficial X-ray therapy is one of the most important treatment methods in radiotherapy especially in the treatment of superficial skin lesions (Up to 300 kVp). Quality of the X-ray beam that can be expressed by Half-Value Layer (HVL), are important indices for this type of treatment effective energy of photon and Homogeneity Coefficient (HC). Materials and Methods The HC of the s...

Journal: :Optics express 2003
J Ronald Zaneveld W Pegau

We review theoretical models to show that contrast reduction at a specific wavelength in the horizontal direction depends directly on the beam attenuation coefficient at that wavelength. If a black target is used, the inherent contrast is always negative unity, so that the visibility of a black target in the horizontal direction depends on a single parameter only. That is not the case for any o...

Journal: :iranian journal of nuclear medicine 2007
dariyush shahbazi-gahrouei zahra shahi kourosh ziaie ehsan khodamoradi

introduction:  the use of radioactive iodine (131i) has become an important adjunct to the treatment of thyroid cancer and hyperthyroidism. salivary gland has the ability to concentrate radioactive iodine under normal circumstances. salivary gland dysfunction and dry mouth are the common side effectsof high-dose radioiodine therapy. the purposeof this study was to determine the absorbed dose of...

مختاری دیزجی , منیژه, واحد , محمدرضا, گیتی , معصومه,

Background and purpose: Tissue differentiation based on measurement of ultrasonic parameters is an ideal gool. Ïn this study, attenuation coefficent measurement in 10 MHZ ultrasonic wave in breast tissue, begin and maliguant paranchymal tissue at 20oc, 25 oc, 30 oc and 35 oc were measured and analyzed. Materials and methods : Dat a were collected from 57 biopsies and mastectomy specimens,...