نتایج جستجو برای: phantom spect imaging system

تعداد نتایج: 2623550  

Journal: :Journal of nuclear medicine technology 1999
D C Vines M Ichise

OBJECTIVE We developed a modification of the acquisition zoom technique, referred to as differential magnification (DM), to improve the pixel resolution with fanbeam collimators. This study evaluated the effects of DM on brain SPECT image quality. METHODS SPECT imaging was performed using a triple-head camera with and without DM for a line source in air, Jaszczak and Hoffman phantoms, and 15 ...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2009
Sanjiv S Gambhir Daniel S Berman Jack Ziffer Michael Nagler Martin Sandler Jim Patton Brian Hutton Tali Sharir Shlomo Ben Haim Simona Ben Haim

UNLABELLED This study described and validated a new solid-state single-photon gamma-camera and compared it with a conventional-SPECT Anger camera. The compact new camera uses a unique method for localizing gamma-photon information with a bank of 9 solid-state detector columns with tungsten collimators that rotate independently. METHODS Several phantom studies were performed comparing the new ...

2004

We compare analytically techniques for multiplephoton coincidence imaging in terms of spatial resolution, detector efficiency (or simply efficiency), and system sensitivity for a spherical water phantom (or simply sensitivity). One analysis consists of comparing photon-photon coincidence single-photon-emission computerized tomography (PP-SPECT) with angularly unconstrained, electronically colli...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2013
Frederic Boisson David Zahra Arvind Parmar Marie-Claude Gregoire Steven R Meikle Hasar Hamse Anthonin Reilhac

UNLABELLED The Inveon small-animal SPECT system comes with several types of multipinhole collimator plates. We evaluate here the performance measurements of the Inveon SPECT system using 6 different collimators: 3 dedicated for mouse imaging and 3 for rat imaging. METHODS The measured performance parameters include the sensitivity, the spatial resolution using line sources, the ultra-micro De...

2013
Hideo Onishi Norikazu Matsutomo Yoshiharu Kangai Tatsunori Saho Hizuru Amijima

OBJECTIVES A novel IQ-SPECT™ method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECT™ (IQ-mode), conventional (180° apart: C-mode) and L-mode (90° apart: L-mode) systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. METHODS SPECT imag...

Journal: :Annals of nuclear medicine 2004
Akihiro Kojima Seiji Tomiguchi Koichi Kawanaka Daisuke Utsunomiya Shinya Shiraishi Takeshi Nakaura Noboru Katsuda Masanori Matsumoto Yasuyuki Yamashita Nobutoku Motomura Takashi Ichihara

For transmission computed tomography (TCT) systems using a centered transmission source with a fan-beam collimator, the transmission projection data are truncated. To achieve sufficiently large imaging field of view (FOV), we have designed the combination of an asymmetric fan-beam (AsF) collimator and a small uncollimated sheet-source for TCT, and implemented AsF sampling on a two-head SPECT sy...

Journal: :Nihon Hoshasen Gijutsu Gakkai zasshi 2006
Hideyuki Iwanaga Yona Oishi Kazuyoshi Suga

PURPOSE A chest phantom study was conducted to evaluate the image quality of newly developed high-speed rotation multiplied projection-single photon emission computed tomography (HSRMP-SPECT) images. MATERIALS AND METHODS HSRMP-SPECT images of a chest phantom consisting of a simulated lung structure filled with 5000 ml of water containing 185 MBq Tc-99m-pertechnetate, and several small 11 mm ...

Ahmad Bitarafan, Faraz Kalantari Hossein Rajabi, Nahid Yaghoobi

Introduction: It is a common protocol to use 201Tl for the rest and 99mTc for the stress cardiac SPECT imaging. Theoretically, both types of imaging may be performed simultaneously using different energy windows for each radionuclide. However, a potential limitation is the cross-contamination of scattered photons from 99mTc and collimator X-rays into the 201Tl energy window. We used a middle en...

2011
Faraz Kalantari Hossein Rajabi Mohsen Saghari Alireza Emami Ardekani

Introduction: Monte Carlo (MC) is the most common method for simulating virtual SPECT projections. It is useful for optimizing procedures, evaluating correction algorithms and more recently image reconstruction as a forward projector in iterative algorithms; however, the main drawback of MC is its long run time. We introduced a model based method considering the effect of body attenuation and i...

2016
Andrew P Robinson Jill Tipping David M Cullen David Hamilton Richard Brown Alex Flynn Christopher Oldfield Emma Page Emlyn Price Andrew Smith Richard Snee

BACKGROUND Patient-specific absorbed dose calculations for molecular radiotherapy require accurate activity quantification. This is commonly derived from Single-Photon Emission Computed Tomography (SPECT) imaging using a calibration factor relating detected counts to known activity in a phantom insert. METHODS A series of phantom inserts, based on the mathematical models underlying many clini...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید