نتایج جستجو برای: perchlorate selective electrode
تعداد نتایج: 263113 فیلتر نتایج به سال:
The voltammetric characteristics of Mo (VI) oxinate at the mercury electrode, in the presence of tri-butylammonium perchlorate (tri-BAP) and piperidinium perchlorate (PP) + piperidine (P) as two different types supporting electrolytes, have been studied in chloroform. With the both supporting electrolytes a two electron irreversible process for the reduction of Mo (VI) oxinate was observe...
چکیده ندارد.
Disinfection by products of haloacetic acids and perchlorate pose significant health risks, even at low microg/l levels in drinking water. A new method for the simultaneous determination of nine haloacetic acids (HAAs) and perchlorate as well as some common anions in one run with ion chromatography was developed. The HAAs tested included mono-, di-, trichloroacetic acids, mono, di-, tribromoace...
a new al(iii) selective membrane based on 5-bromo(salicylidene-2-amino thiophenol) as a neutral carrier in a poly(vinyl chloride) (pvc) matrix is coated on platinum wire to determine trace amounts of al(iii) ion in various samples. the sensor exhibits a good response for al(iii) ion over a wide concentration range of 5.20 × 10-7 to 1.00 × 10-2 m with nernstian slope of 19.64 ± 0.15 mv decade-1...
the voltammetric characteristics of mo (vi) oxinate at the mercury electrode, in the presence of tri-butylammonium perchlorate (tri-bap) and piperidinium perchlorate (pp) + piperidine (p) as two different types supporting electrolytes, have been studied in chloroform. with the both supporting electrolytes a two electron irreversible process for the reduction of mo (vi) oxinate was observed. p...
tin(ii)-ion-selective electrode consisting of dibenzo-18-crown-6 (db18c6) as an ionophore inpvc matrix was developed. the influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. the electrodeshowed a near nernstian response for sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27...
in order to study the cu(ii) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of pvc powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. the sensor showed a near nernstian response for cu(ii) ions over a concentration range from 1.0×0-6 –1.0×0-2 m with a slope of 28.90.5 mv per concentration decade with a working ph range of 3.5-6.3. ...
in order to preparing strontium ion selective electrode 6-(4- nitropheny1)-2-pheny14, 4- dipropy1-3, 5-diaza-bicyclo [3, 1, 0] hex-2-ene (npdbh) was used as an ionophore. this electrode responds to sr (ii)ion with a sensitivity of 28.2 ± 0.5 mv/decade over the range 1.0 x 10-6 to 1.0 mat ph 3.0-10.0. thelimit of detection was 2.4 x 10-7 m. the influences of membrane composition, the ph of the t...
چکیده ندارد.
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید