نتایج جستجو برای: peeling

تعداد نتایج: 2768  

Journal: :Annals of plastic surgery 2005
Jacob Golan Noam Hai

JetPeel (Tav-Tech Ltd., Yehud, Israel) is a new device for cosmetic resurfacing of the facial skin. It uses a new technology of a 2-phase stream that creates a jet composed of gas (oxygen) and microdroplets of fluid (saline) accelerated to supersonic velocities. This jet impacts the skin, causing gentle and accurate cosmetic peeling. Our preclinical and clinical experience with the JetPeel for ...

Journal: :Trials 2008
Noemi Lois Jennifer Burr John Norrie Luke Vale Jonathan Cook Alison McDonald

BACKGROUND A full-thickness macular hole (FTMH) is a common retinal condition associated with impaired vision. Randomised controlled trials (RCTs) have demonstrated that surgery, by means of pars plana vitrectomy and post-operative intraocular tamponade with gas, is effective for stage 2, 3 and 4 FTMH. Internal limiting membrane (ILM) peeling has been introduced as an additional surgical manoeu...

Journal: :Archives of ophthalmology 2006
Mohan N Iyer Dennis P Han

A cost-effective, reusable practice eye model for epiretinal membrane peeling that uses easily obtained, commercially available materials was developed. A commercially available globe that is anatomically and optically similar to the human eye was modified by creating 2 ports that simulate superior sclerotomies. The model has a removable plastic anterior segment, which allows access to the post...

Journal: :Electr. J. Comb. 2016
Timothy Budd

We start by studying a peeling process on finite random planar maps with faces of arbitrary degrees determined by a general weight sequence, which satisfies an admissibility criterion. The corresponding perimeter process is identified as a biased random walk, in terms of which the admissibility criterion has a very simple interpretation. The finite random planar maps under consideration were re...

2012
Nikul D. Patel Satyam P. Patel Aniskhan Pathan

. Abstract—The demand for high quality focuses attention on the surface condition of the product, especially the roughness of the machined surface, because of its effect on product appearance, function, and reliability. Surface quality is one of the specified customer requirements for machined parts. There are many parameters that have an effect on surface roughness such as cutting speed, feed ...

Journal: :Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention 2010
Marcin Balicki Ali Uneri Iulian Iordachita James Handa Peter Gehlbach Russell H. Taylor

Vitreoretinal surgeons use 0.5 mm diameter instruments to manipulate delicate tissue inside the eye while applying imperceptible forces that can cause damage to the retina. We present a system which robotically regulates user-applied forces to the tissue, to minimize the risk of retinal hemorrhage or tear during membrane peeling, a common task in vitreoretinal surgery. Our research platform is ...

Journal: :iranian journal of public health 0
mostafa leili amin pirmoghani mohammad taghi samadi reza shokoohi ghodratollah roshanaei ali poormohammadi

background: the objective of this study was to determine the residual concentrations of ethion and imidacloprid in cucumbers grown in greenhouse. the effect of some simple processing procedures on both ethion and imidacloprid residues were also studied. methods: ten active greenhouses that produce cucumber were randomly selected. ethion and imidacloprid as the most widely used pesticides were m...

2016
Zhen Gu Siheng Li Feilong Zhang Shutao Wang

Nature often exhibits various interesting and unique adhesive surfaces. The attempt to understand the natural adhesion phenomena can continuously guide the design of artificial adhesive surfaces by proposing simplified models of surface adhesion. Among those models, a peeling model can often effectively reflect the adhesive property between two surfaces during their attachment and detachment pr...

Journal: :Archives of ophthalmology 2005
Naoichi Horio Masayuki Horiguchi Naoki Yamamoto

W e have developed a new technique to facilitate internal limiting membrane (ILM) peeling with triamcinolone acetonide during idiopathic macular hole surgery. Twelve eyes of 12 patients with a macular hole, stage 2 to 4 and size 0.12 disc diameters (DD) to 0.39 DD (mean, 0.20 DD), underwent vitrectomy with ILM peeling using triamcinolone. Before ILM peeling, a triamcinolone suspension (8 mg/mL ...

2014
Jeremy O. Marston Paul W. Riker Sigurdur T. Thoroddsen

We investigate the generation of the screeching sound commonly heard during tape peeling using synchronised high-speed video and audio acquisition. We determine the peak frequencies in the audio spectrum and, in addition to a peak frequency at the upper end of the audible range (around 20 kHz), we find an unexpected strong sound with a high-frequency far above the audible range, typically aroun...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید