نتایج جستجو برای: ovarian stimulator

تعداد نتایج: 90523  

2014
Changho Seok Hyunho Kim Seunghyun Im Haryong Song Kyomook Lim Yong-Sook Goo Kyo-in Koo Dong-il Cho Hyoungho Ko

The neural stimulators have been employed to the visual prostheses system based on the functional electrical stimulation (FES). Due to the size limitation of the implantable device, the smaller area of the unit current driver pixel is highly desired for higher resolution current stimulation system. This paper presents a 16-channel compact current-mode neural stimulator IC with digital to analog...

1999
E. Ott M. Munih A. Kralj

Abstract: Microprocessor based, surface electrodes peroneal nerve stimulator that allows voluntary control of the stimulation has been developed. Easiness of use, minimum required maintenance and the compliance with the EC requirements were the main design goals. Radio frequency link between the crutch mounted push-button and the stimulator enables the patient to control the timing of stimulati...

2017
Xiaoran Li Shunan Zhong James Morizio

BACKGROUND Neural stimulation is an important method used to activate or inhibit action potentials of the neuronal anatomical targets found in the brain, central nerve and peripheral nerve. The neural stimulator system produces biphasic pulses that deliver balanced charge into tissue from single or multichannel electrodes. The timing and amplitude of these biphasic pulses are precisely controll...

Journal: :Journal of neuroscience methods 1995
F S Jaw S J Liu T S Kuo C Y Wang

A low-cost PC-based 2-channel stimulator was designed. This device can generate regular current pulses for many neuroscience experiments. It can also generate irregular pulses for nerve stimulation, thus could possibly avoid the problem of sensitization or habituation in the central nervous system. The stimulation frequency (can be < 0.0005 Hz) and pulse duration (5 microseconds to 65 ms) of th...

Journal: :Stereotactic and functional neurosurgery 2008
Xiaodong Guo Guodong Gao Xuelian Wang Lihong Li Weixin Li Qinchuan Liang Hua Zhang

OBJECTIVE The goal of the present study was to evaluate the effects of bilateral deep brain stimulation (DBS) of the subthalamic nucleus (STN) on olfaction in patients with Parkinson's disease (PD). METHODS 15 patients suffering from sporadic PD-related dysosmia were implanted with bilateral electrodes aimed at the STN. One week before the surgery, odor detection threshold (DT) and identifica...

Journal: :JAPANES JOURNAL OF MEDICAL INSTRUMENTATION 1954

Journal: :Journal of neurophysiology 2000
A V Apkarian P A Gelnar B R Krauss N M Szeverenyi

Cortical activity patterns to thermal painful stimuli of two different sizes were examined in normal volunteers using functional magnetic resonance imaging (fMRI). Seven right-handed subjects were studied when the painful stimulus applied to the right hand fingers covered either 1,074-mm(2)-area large stimulator or 21-mm(2)-area small stimulator. Stimulus temperatures were adjusted to give rise...

2010
Petar Lukic Petar Lukić Aleksandar Žunjić

The paper proposes a new ergonomic and electronic solution for the muscle stimulator. The device is programmable. It can be easily adjusted by the doctor, as well as by the patient. The design solution of this muscle stimulator has the improved interface. The device is safe to use and has determined ergonomic improvements. This muscle stimulator has small dimensions and light weight. The propos...

Journal: :Chest 2005
Jagdeep S Bijwadia Robert C Hoch Donn D Dexter

We evaluated a 63-year-old woman who developed dyspnea with a sensation of chest tightness that was temporally associated with discharges from a vagus nerve stimulator that had been implanted for the control of intractable seizures. Spirometry demonstrated the development of significant airflow obstruction associated with the firing of the stimulator. Adjustment of the stimulator settings resol...

2014
Giovanni Bianchin Valeria Polizzi

Objective: We report the case of a patient with a previously implanted spinal cord stimulator (SCS) who presented for a cochlear implant. The patient was successfully implanted with a Nucleus CI422 Slim Straight Electrode from Cochlear Company. Methods: The authors conducted a case report and literature review. Results: Successful hookup and mapping of the device was performed 1 month and 6 mon...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید