نتایج جستجو برای: normoxic polymer gel
تعداد نتایج: 197226 فیلتر نتایج به سال:
introduction the use of cut-outs in electron applicators make changes on output, isodose, and percentage depth dose (pdd) curves. these changes and electron beam dose distribution in the form of three-dimensional (3d) can be measured by gel dosimeters. materials and methods dosimetry was performed with and without a square shield (6×6 cm2 field). the energies were 4, 9, and 16 mev and phantom w...
Introduction The use of cut-outs in electron applicators make changes on output, isodose, and percentage depth dose (PDD) curves. These changes and electron beam dose distribution in the form of three-dimensional (3D) can be measured by gel dosimeters. Materials and Methods Dosimetry was performed with and without a square shield (6×6 cm2 field). The energies were 4, 9, and 16 MeV and phantom w...
introduction the purpose of the current study was to determine optical sensitivity of n-isopropyl acrylamide nipam and polyacrylamide gelatin and tetrakis hydroxymethyl phosphoniun chloride (pagat) polymer gels for different wavelength of visible light spectrum applied in optical computed tomography method. materials and methods nipam and pagat polymer gels with conventional formulations used f...
Introduction: Polymer gels are modern dosimeters providing three dimensional dose distributions. These dosimeters can be used in brachytherapy in which the tumor dimension is relatively small and the dose gradient is high. In this study, the ability of the MAGICA polymer gel was investigated for assessing the absolute dose values as well as the dose distribution of low dose rate (LDR) Ir-192 wi...
Introduction: Three physical conditions caused an external beam designated as a small field. The first is the loss of lateral charged particle equilibrium. The second is the effect of collimators on the primary photon source occlusion. The third condition is the size of the detector which is large compared to the field size. The most obvious perturbation effects in last condit...
Excessive water production through fractures become an important problem in oil exploration of fractured reservoirs. For this purpose, polymer gels were prepared by crosslinking of aqueous solutions of polymer and crosslinker for the purpose of water management in high water cut fractured reservoirs. A copolymer of sulfonated polyacrylamide was used as polymer and chromium triacetate (Cr(OA...
background: in this study the basic radiation properties of n-isopropylacrylamaide polymer gel dosimeter were determined together with verification of its soft tissue equivalency. materials and methods: the nipam gel was prepared and irradiated approximately 2 h after manufacturing. the magnetic resonance (mr) images were made 24 h after irradiation. the nuclear magnetic resonance (nmr) respons...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید