نتایج جستجو برای: net analyte signal

تعداد نتایج: 520623  

2006
JIANAN Y. QU

An approach coupling signal processing and partial least-squares regression analysis (PLS) is described in which raw spectral data are processed with a multiple band-pass Ž lter and the Ž ltered spectra are used in a PLS to build a calibration model for the analyte of interest. The multiple band-pass Ž lter is speciŽ cally designed for a desired analyte based on the Fourier frequency characteri...

Journal: :Water science and technology : a journal of the International Association on Water Pollution Research 2012
Yahya S Al-Degs Amjad H El-Sheikh Ayman A Issa Mohammad A Al-Ghouti Mahmoud Sunjuk

A simple analytical procedure is proposed for simultaneous determination of three common dyes (Basic Blue 9, Brilliant Blue E-4BA, and Reactive Blue 2) in natural waters without prior separation of the solutes. A popular chemometric method, partial least squares regression PLS-1, was effectively applied for spectral resolution of a highly overlapping system. At the best modeling conditions, mea...

Journal: :Journal of biomedical optics 2005
Vidi Saptari Kamal Youcef-Toumi

Near-infrared measurements of glucose in human plasma are performed using a custom, rapid, high-throughput filter-based spectrometer covering a spectral range between 2080 and 2315 nm. Quality of the measured glucose signals is quantified through the use of two figures of merit: selectivity and limit of detection. Selectivity measures the uniqueness of the glucose spectrum from among the interf...

Journal: :Journal of Analytical Atomic Spectrometry 2023

Line-dependent analyte signal suppression/enhancement by 18 common matrix elements was simultaneously investigated for MIP-OES. Li caused the strongest effect, even concentrations as low 20 mg L −1 .

Journal: :Nature communications 2016
Kazunori Koide Matthew P Tracey Xiaodong Bu Junyong Jo Michael J Williams Christopher J Welch

Catalysis-based signal amplification makes optical assays highly sensitive and widely useful in chemical and biochemical research. However, assays must be fine-tuned to avoid signal saturation, substrate depletion and nonlinear performance. Furthermore, once stopped, such assays cannot be restarted, limiting the dynamic range to two orders of magnitude with respect to analyte concentrations. In...

Journal: :Chemosensors 2022

We leveraged chemical-induced changes to microwave signal propagation characteristics (i.e., S-parameters) characterize the detection of aliphatic alcohol (methanol, ethanol, and 2-propanol) vapors using TCNQ-doped HKUST-1 metal-organic-framework films as sensing material, at temperatures under 100 °C. show that sensitivity depends on oxidation potential analyte, impedance setup analyte-loading...

Journal: :Analytical chemistry 2008
Jennifer R W Furchak Peilin Yang Colin Jennings Nils G Walter Robert T Kennedy

A naturally occurring aptazyme, the glmS ribozyme, is adapted to an assay for glucosamine 6-phosphate, an effector molecule for the aptazyme. In the assay, binding of analyte allosterically activates aptazyme to cleave a fluorescently labeled oligonucleotide substrate. The extent of reaction, and hence analyte concentration, is detected by either fluorescence resonance energy transfer (FRET) or...

Journal: :international journal of information science and management 0
a. zolghadrasli ph.d., department of electrical engineering, school of engineering, shiraz university

in this paper the author considers a general method, based on time domain samples for spectral manipulation of time limited signals. first, the original signal is divided into some frames in the time domain. then, by presenting a suitable theoretical and computational algorithm, and using a method for improving the speed of convergence, we find the local bandwidth of each frame; thereby, each f...

2017
Khulan Sergelen Stefan Fossati Aysegül Turupcu Chris Oostenbrink Bo Liedberg Wolfgang Knoll Jakub Dostálek

Surface plasmon field-enhanced fluorescence energy transfer is employed for sensitive optical readout of a reversible hairpin aptamer assay that is suitable for continuous monitoring of low-molecular-weight chemical analytes. A hairpin aptamer specific to adenosine and adenosine triphosphate with Alexa Fluor 647 fluorophore attached to its 5' end was anchored via 3' end thiol to a gold thin fil...

Journal: :ACS applied polymer materials 2022

We present the design, tailoring, and physicochemical properties of a multicomponent polyethylene glycol (PEG)-based polymer doped with spherical nanoparticles modified lipoic acid derivative cyclodextrin its application for electrochemical sensing ferrocene ibuprofen at low concentrations. Each components this hybrid material has specific that can be useful preparation sensors characterized by...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید