نتایج جستجو برای: negative temperature coefficient thermistor

تعداد نتایج: 1114480  

Journal: :Optics express 2015
Monuko du Plessis Hanqing Wen Enrico Bellotti

Emission spectra of avalanching n(+)p junctions manufactured in a standard CMOS technology with no process modifications were measured over a broad photon energy spectrum ranging from 0.8 eV to 2.8 eV at various temperatures. The temperature coefficients of the emission rates at different photon energies were determined. Below a photon energy of 1.35 eV the temperature coefficient of emission w...

Journal: :Carbon 2022

Ti-doped polymer-derived SiOC ceramic has multi-functional sensing capability due to its semiconductive properties. Their mechanical and chemical stability provide reliable support for their long-term service safe operation in extreme environments. The properties of (SiTiOC) can be optimized by modulation carrier concentration. Meanwhile, it fabricated 3D printing as structural-strengthened com...

2005
Liliana Giraldo-Gutierréz Juan Carlos Moreno-Piraján

An isoperibolic calorimetric cell is built with glass surrounded by plastic insulation. The cell has a lid on which a thermistor thermometer, an electric resistance to provide the cell with definite quantities of electric work and a container for a glass ampoule, are placed. For measuring the thermal changes, an NTC thermistor, which provides an electric resistance signal that varies with tempe...

Journal: :Clinical chemistry 1980
R L Berger T Clem C Gibson W Siwek M Sapoff

We describe a digitally linearized thermistor thermometer that is accurate to +/- 0.01 degrees C from 0 to 60 degrees C at a wattage of 50 microW and a sampling time of 1 s. It is traceable to the International Practical Temperature Scale of 1968 (IPTS-68). Analog and digital outputs are provided, the latter as ASCII RS-232C. The thermistor is a 10-cm long immersible probe, 1.5 mm in diameter. ...

2017
Devon Bridgeman Francis Tsow Xiaojun Xian Qinan Chang Yongming Liu Erica Forzani

We present a new method of chemical quantification utilizing thermal analysis for the detection of relative humidity. By measuring the temperature change of a hydrophilically-modified temperature sensing element vs. a hydrophobically-modified reference element, the total heat from chemical interactions in the sensing element can be measured and used to calculate a change in relative humidity. W...

Journal: :Scandinavian journal of clinical and laboratory investigation. Supplementum 1964
V GANZ A HLAVOVA A FRONEK J LINHART I PREROVSKY

IN 1960 we reported a method of measuring blood flow in individual vessels based on the principle of local thermodilution.1 The present communication presents application of the same principle to measurement of blood flow in the femoral artery in man at rest and during exercise. Methods An upstream catheter was used, modified to allow for percutaneous insertion by the Seldinger technic (fig. 1)...

Journal: :SIAM J. Control and Optimization 2017
H. Meinlschmidt Christian Meyer Joachim Rehberg

This paper is concerned with the state-constrained optimal control of the threedimensional thermistor problem, a fully quasilinear coupled system of a parabolic and elliptic PDE with mixed boundary conditions. This system models the heating of a conducting material by means of direct current. Local existence, uniqueness and continuity for the state system are derived by employing maximal parabo...

2010
Debangshu Dey Sugata Munshi

This paper presents a novel and cheap electronic version of wet and dry temperature hygrometer The instrument is centered around a 555 timer, operated in astable multivibrator mode. Two thermistors with negative temperature coefficients (NTC) serve as the two timing resistors of the multivibrator. These thermistors are used to sense the dry and wet temperatures. The durations of the ‘HIGH’ and ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید