نتایج جستجو برای: multi focus fan beam collimator
تعداد نتایج: 906544 فیلتر نتایج به سال:
Treatment of small animals with radiation has in general been limited to planar fields shaped with lead blocks, complicating spatial localization of dose and treatment of deep-seated targets. In order to advance laboratory radiotherapy toward what is accomplished in the clinic, we have constructed a variable aperture collimator for use in shaping the beam of microCT scanner. This unit can image...
The design, physical properties and clinical utility of an iris collimator for robotic radiosurgery.
Robotic radiosurgery using more than one circular collimator can improve treatment plan quality and reduce total monitor units (MU). The rationale for an iris collimator that allows the field size to be varied during treatment delivery is to enable the benefits of multiple-field-size treatments to be realized with no increase in treatment time due to collimator exchange or multiple traversals o...
An inversion formula was developed by Bukhgeim and Kazantsev for attenuated fan-beam projections [Russian Academy of Science Siberian Branch: The Sobolev Institute of Mathematics (2002)]. The inversion formula was obtained by relating the attenuated fan-beam projections to unattenuated fan-beam projections and by trickily processing the unattenuated fan-beam projections. We show in this paper t...
We are developing an acceptance measurement system to evaluate the matching of the emittance of an injection beam to the acceptance of the AVF cyclotron. The system is composed of a phase-space collimator in the low energy section and beam intensity monitors which are installed just after the phase space collimator and in the high energy section. The phase-space collimator, which consists of tw...
Collimator systems used in Intensity Modulated Radiation Therapy can form different geometric aperture shapes depending on their physical capabilities. We compare the efficiency of using regular, rotating and dual multileaf collimator (MLC) systems under different combinations of consecutiveness, interdigitation and rectangular constraints. We also create a virtual freeform collimator, which ca...
designing FIR fan filters suitable for the multibeam forming network of the wideband beamspace adaptive array. Characteristics were approximated through the combination of spectral transformation and the window method so that those beam patterns that included the sidelobe characteristics of the resulting fan filters were virtually frequency independent. Using the fan filters designed by the pro...
This paper presents analytical fan-beam and cone-beam reconstruction algorithms that compensate for uniform attenuation in single photon emission computed tomography. First, a fan-beam algorithm is developed by obtaining a relationship between the two-dimensional (2D) Fourier transform of parallel-beam projections and fan-beam projections. Using this relationship, 2D Fourier transforms of equiv...
The accuracy of external beam radiotherapy has improved rapidly in recent years with the advancement of technology. New modalities like three‐dimensional (3D) conformal radiotherapy, IMRT (intensity modulated radiotherapy) based on multi‐leaf collimator (MLC) and Tomotherapy technology for cancer treatments have been adopted in radiotherapy centers. In many developing countries like India these...
In order to perform fan-beam reconstruction using projection data collected from a noncircular scanning locus, existing noncircular fan-beam formulas require a derivative of the scanning locus with respect to the rotation angle. A derivative-free noncircular fan-beam reconstruction formula that is based on a geometrical explanation of the circular equispatial fan-beam reconstruction formula is ...
More and more camera concepts are being investigated to try and seize the opportunity of instantaneous range verification of proton therapy treatments offered by prompt gammas emitted along the proton tracks. Focusing on one-dimensional imaging with a passive collimator, the present study experimentally compared in combination with the first, clinically compatible, dedicated camera device the p...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید