نتایج جستجو برای: mtwo r

تعداد نتایج: 446993  

2018
Emmanuel João Nogueira Leal Silva Felipe Gonçalves Belladonna Marianna Fernandes Carapiá Brenda Leite Muniz Mariana Santoro Rocha Edson Jorge Lima Moreira

Objectives This study evaluated the amount of remaining root canal filling materials after retreatment procedures performed by undergraduate students using manual, rotary, and reciprocating techniques through micro-computed tomographic analysis. The incidence of instrument fracture and the instrumentation time were also evaluated. Materials and Methods Thirty maxillary single rooted teeth wer...

2010
Maryam Bidar Saeed Moradi Maryam Forghani Salma Bidad Mahtab Azghadi Shahrzad Rezvani Shirin Khoynezhad

INTRODUCTION This study compared the cleaning efficiency of Mtwo, Race and Medin Nickel-Titanium (NiTi) rotary instruments. MATERIALS AND METHODS Sixty mandibular molar mesial roots were selected with angle curvatures between 25-35 degrees and divided into three groups; each containing 20 teeth. Canals were prepared with the rotary files and irrigated with 2.5% NaOCl solution after each instr...

2013
Ali Talati Saeed Moradi Maryam Forghani Ali Monajemzadeh

INTRODUCTION Disinfection and subsequent obturation of the root canal space require adequate mechanical enlargement of the canals. The purpose of this in vitro study was to compare the shaping ability of Mtwo, RaCe and Medin rotary instruments during the preparation of curved root canals. MATERIALS AND METHODS Sixty mesiobuccal root canals of mandibular molars with severe curvatures between 2...

Journal: :Journal of endodontics 2010
Manoel Eduardo de Lima Machado Luiz Antônio Bichels Sapia Silvana Cai Guilherme Henrique Rosa Martins Cleber Keiti Nabeshima

INTRODUCTION The aim of the present study was to determine the disinfection of preparations carried out by using the Protaper or MTwo system in canals infected with Enterococcus faecalis. METHODS Twenty-eight distobuccal canals of upper molars were used, in which the canals were sterilized after being enlarged to #20 file and then contaminated with an inoculation of a culture of E. faecalis. ...

2018
Iussif Mamede-Neto Álvaro Henrique Borges Ana Helena Gonçalves Alencar Marco Antonio Hungaro Duarte Manoel Damião Sousa Neto Carlos Estrela

Objective To evaluate transportation (T) and centering ability (CA) of root canal preparations using continuous or reciprocating nickel-titanium endodontic files. Materials and Methods Ninety-six mesiobuccal root canals of mandibular first and second molars were randomly divided into 6 groups (n=16) according to the rotary file used: 1. ProTaper Next; 2. ProTaper Gold; 3. Mtwo; 4. BioRaCe; 5....

2012
Gianluca Plotino Dina Al-Sudani Stefano Pulino Nicola M. Grande Piero Alessandro Marcoli Silvia Pizzi Luca Testarelli Gianluca Gambarini

BACKGROUND The aim of the present study was to evaluate the cyclic fatigue resistance of Mtwo NiTi rotary instruments after clinical use by 1 experienced and 1 novice operator. MATERIAL/METHODS Cyclic fatigue testing of instruments was performed on tapered artificial canals with a 5 mm radius of curvature and 60° angle of curvature. Twenty Mtwo instruments for each size were selected and divid...

Journal: :Medicina oral, patologia oral y cirugia bucal 2009
Milagros Martín-Micó Leopoldo Forner-Navarro Amelia Almenar-García

OBJECTIVE To determine variation in post-instrumentation working length and root area in the following rotary systems: ProTaper, RaCe, Mtwo and K3. STUDY DESIGN A sample of 40 resin blocks with double curvature (at 14 and 16 mm) and a 33 degrees angle was used. Working length was verified with a digital measure using a number 10 K file. The specific sequence for each rotary system was followe...

Journal: :Acta odontologica latinoamericana : AOL 2013
Javier L Niño-Barrera Mara C Aguilera-Cañón Carlos J Cortes-Rodríguez

Nickel-Titanium rotary files are a technological development that enables dentists to prepare irregularly shaped root canals without altering them. Unfortunately, these files may fracture without any prior visible warning signs. The aim of this study was to perform a theoretical evaluation of the mechanical behaviour of Mtwo Nickel-Titanium rotary files for endodontics, in order to determine wh...

2014
Zahra Sadat Madani Azam Haddadi Sina Haghanifar Ali Bijani

INTRODUCTION Due to the importance of apical transportation during root canal preparation, the aim of the current study was to use cone-beam computed tomography (CBCT) to assess the extent of apical transportation caused by ProTaper and Mtwo files. METHODS AND MATERIALS Forty extracted maxillary first molars with 19-22 mm length and 20-40 degrees of curvature were selected. The mesiobuccal ca...

2016
Dilek Erbay Turkaydin Mahir Gunday

The purpose of this investigation was to compare centring ratio of ProTaper and Mtwo rotary systems. 60 mandibular molar teeth which had 25, 30 and 35 degree curvature in mesio-buccal root canal were used. Group 1 had 25°, Group 2 had 30°, and Group 3 had 35° curvatures. The roots were sectioned horizontally at 2 mm away from the apex. The apical region was then observed under a stereo-microsco...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید