نتایج جستجو برای: magic f polymer gel dosimeters

تعداد نتایج: 505330  

2017
Rahim Sabbaghizadeh Roslinda Shamsudin Najmeh Deyhimihaghighi Arman Sedghi

In the present study, the normoxic polyacrylamide gelatin and tetrakis hydroxy methyl phosphoniun chloride (PAGAT) polymer gel dosimeters were synthesized with and without the presence of silver (Ag) nanoparticles. The amount of Ag nanoparticles varied from 1 to 3 ml with concentration 3.14 g/l, thus forming two types of PAGAT polymer gel dosimeters before irradiating them with 6 to 25 Gy produ...

Azim Arbabi Bahram Bolouri Hasan Nedaie Ruhollah Ghahraman Asl

Introduction: Nowadays radiosensitive polymer gels are used as a reliable dosimetry tool for verification of 3D dose distributions. Special characteristics of these dosimeters have made them useful for verification of complex dose distributions in clinical situations. The aim of this work was to evaluate the capability of a normoxic polymer gel to determine electron dose distributions in differ...

Journal: :iranian journal of radiation research 0
a.r. farajollahi department of medical physics, faculty of medicine, tabriz university of medical sciences, tabriz, iran f. pak department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran m. horsfield department of cardiovascular sciences, university of leicester, leicester royal infirmary, leicester, uk z. myabi department of radiology, emam reza teaching hospital, tabriz university of medical sciences, tabriz, iran

background: in this study the basic radiation properties of n-isopropylacrylamaide polymer gel dosimeter were determined together with verification of its soft tissue equivalency. materials and methods: the nipam gel was prepared and irradiated approximately 2 h after manufacturing. the magnetic resonance (mr) images were made 24 h after irradiation. the nuclear magnetic resonance (nmr) respons...

M. Allahverdi, M.H. Zahmatkesh, Mahbod Sedaghat, R. Jaberi, Sh. Akhlaghpoor,

ABSTRACTBackground: Polymer gels are an emerging new class of dosimeters which are being applied to the challenges of modern radiotherapy modalities. Research on gel dosimetry involves several scientific domains, one of which is the imaging techniques with which dose data is extracted from the dosimeters. In the current work, we present our preliminary results of investigating capability of X-r...

Journal: :iranian journal of medical physics 0
m. sedaghat ph.d. student in medical physics, university of sherbrooke, canada. m.h zahmatkesh assistant professor, novin medical radiation institute, tehran, iran. r. jaberi m.sc. in medical physics, cancer institute, imam hospital, tums, tehran, iran. sh. akhalghpoor assistant professor, faculty of medicine, tums & novin medical radiation institute, tehran, iran. m. allahverdi assistant professor, dept. of medical physics, faculty of medicine, tums & cancer institute of imam hospital, tehran, iran.

introduction: despite the fact that the clinical implementation of polymer gel dosimetry has been facilitated after the introduction of normoxic gels, there are still complications in its clinical routine use that are under investigation. in the current work, the feasibility of using a normoxic polymer gel dosimeter named magica has been investigated for use in our clinical brachytherapy applic...

Journal: :Journal of Radioanalytical and Nuclear Chemistry 2022

Abstract Three different dosimetry systems were prepared based on diphenyl thiocarbazone (DTH) dye: polymer films made with, poly(vinyl alcohol), DTH liquid dosimeter and gel dosimeter. All the received several gamma doses. The three analyzing by UV–Vis spectrophotometery before after irradiation. effective dose range in linear part of these is between 1–10 kGy, 0.3–2 50–200 Gy. dosimeters reli...

Journal: :The British journal of radiology 2000
M McJury M Oldham V P Cosgrove P S Murphy S Doran M O Leach S Webb

New, complex radiotherapy delivery techniques require dosimeters that are able to measure complex three-dimensional dose distributions accurately and with good spatial resolution. Polymer gel is an emerging new dosimeter being applied to these challenges. The aim of this review is to present a practical overview of polymer gel dosimetry, including gel manufacture, imaging, calibration and appli...

Mahmoud Allahverdi Mohammad Hasan Zahmatkesh Tayeb Allahverdi Pourfallah,

Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...

Azim Arbabi Hadis Ansari Mehr1, Mahmood Allahverdi Mohammad Hasan Zahmatkesh Saeid Bagheri

Introduction The use of cut-outs in electron applicators make changes on output, isodose, and percentage depth dose (PDD) curves. These changes and electron beam dose distribution in the form of three-dimensional (3D) can be measured by gel dosimeters. Materials and Methods Dosimetry was performed with and without a square shield (6×6 cm2 field). The energies were 4, 9, and 16 MeV and phantom w...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید